INSTALL MOUNTING

INSTALL MOUNTING

BRACKET

1.Construct wood wall framing that is flush with interior surface of wall studs.

Make sure:

a)the framing is centered over installation location.

b)the height of the framing will allow the mounting bracket to be secured to the framing within the dimensions shown.

2.After wall surface is finished, secure mount- ing bracket to framing using dimensions shown.

FRAMING BEHIND DRYWALL

37-

 

 

 

 

7/16”

to

43-

 

above

 

7/16”

 

cooktop

37-7/16"= bottom of hood 24" above cooktop

43-7/16"= bottom of hood 30" above cooktop

INSTALL FLUE MOUNTING BRACKET

DUCTED AND NON-DUCTED

1.Assemble the flue mounting bracket, adjusting outside width as shown. Fig.4

2.Carefully center the mounting bracket directly over the range hood location.

3.Secure the bracket assembly to the ceiling using (2) 4.8x38mm mounting screws and drywall anchors. Make sure the bracket is pushed into the corner, tight against the wall and centered over the hood.

FLUE MOUNTING

3.9 x 6 mm

 

BRACKET

 

 

FLAT HEAD

 

BRACKET SCREWS

 

9-13/16”

 

 

(249.8mm)

 

 

 

FIG.

4

MOUNT THE PLATE

Mount the plate of the electrical system attaching it with (2) mounting screws (3.9x9.5mm).

- 7 -

MOUNTING SCREWS

PLATE OF

(3.9x9.5mm)

THE

 

 

ELECTRICAL

 

SYSTEM