Broan RP Cleaning & Maintenance, Operation, Prepare Hood Location, Heat Sentry, Rp Series Hood

Models: AP1 RP

1 16
Download 16 pages 30.62 Kb
Page 2
Image 2
CLEANING & MAINTENANCE

AP1 & RP SERIES

CLEANING & MAINTENANCE

For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces. Use only a clean cloth and mild detergent solution on stainless and painted surfaces. Clean all- metal filters in the dishwasher.

The motor is permanently lubricated and never needs oiling. If the motor bearings make excessive or unusual noise, replace the motor with the exact service motor. The impeller should also be replaced.

Use 120 V, 50 W, shielded halogen bulbs - MR16 or PAR16 with GU10 base. Purchase bulbs separately.

The grease filters, bottom panel, and blower wheel should be cleaned frequently. Use a warm detergent solution. The grease filters and blower wheel are dishwasher safe.

Note: Some minerals, when in contact with dishwasher soap additives, may cause filters to discolor. This discol- oration is not covered by the warranty.

OPERATION

Always turn the hood ON before cooking in order to establish an air flow in the kitchen. After turning off the range, let the hood run for a few minutes to clear the air.

HEAT SENTRY™

The hood is equipped with a Heat Sentry™ thermostat.This safety device will turn on or speed up the blower if it senses excess heat above the cooking surface.

If the blower is not on, or if it is running at low speed, the Heat Senttry™ will override the normal blower control and trun the blower on the high speed. When the temperature level drops to normal levels, the blower will return to its original setting.

RP SERIES HOOD

Operate the hood as follows:

Page 2

AP SERIES HOOD

Operate the hood as follows:

ON

FAN OFF

FAN

LIGHT

FAN

The 2-position switch (in center) turns blower ON and OFF. The 5-position switch (at left) controls blower speed.

OPERATION Blower is OFF (secondary blower OFF).

HEAT SENTRY™ Blower is ON at highest speed.

RP SERIES HOODAP SERIES HOODLIGHT As dots get smaller - blower speed decreases.

LIGHT

This 3-position switch (at right) turns lights ON and OFF and controls their intensity.

PREPARE HOOD LOCATION Lights are OFF.

 BLOWER SWITCH Lights are ON to low intensity.  LIGHT SWITCH Lights are ON to highest intensity.

PREPARE HOOD LOCATION

ROOF CAP

3¼" X 10" (For vertical discharge)

Manual background BLOWER SWITCH

This 3-position switch turns blower ON and OFF and controls blower speed.

Set switch to (1) position to turn blower ON to low speed. Set switch to (2) position to turn blower ON to high speed. Set switch to (0) position to turn blower OFF.

SOFFIT

CABINET

HOOD

18" - 24" ABOVE

COOKING SURFACE

HOUSE WIRING (Top or Back of hood)

WALL CAP

Manual background 3¼" X 10" DUCT

(For horizontal discharge)

Manual background LIGHT SWITCH

This 3-position switch turns lights ON and OFF and controls their intensity.

Set switch to (1) position to turn lights ON to low intensity. Set switch to (2) position to turn lights ON to high intensity. Set switch to (0) position to turn lights OFF.

1 Determine whether hood will discharge vertically or hori- Manual background zontally. For vertical or horizontal discharge, run ductwork between the hood location and a roof cap or wall cap. For best results, use a minimum number of transitions and

elbows.

Page 2
Image 2
Broan RP, AP1 Cleaning & Maintenance, Operation, Prepare Hood Location, Heat Sentry, Rp Series Hood, Ap Series Hood, Light