Broan VX12000C TROUBLESHOOTING GUIDE cont’d, Internal Wiring Diagram, Trouble, Possible Cause

Models: VX12000C

1 8
Download 8 pages 7.82 Kb
Page 5
Image 5
TROUBLESHOOTING GUIDE (cont’d)

page 5

TROUBLESHOOTING GUIDE (cont’d)

Trouble

Possible Cause

Possible Remedy

 

 

 

3.Power unit fails to stop when the hose is removed.

3a.An electrical short has occurred somewhere in the system.

3a.A complete check of all wall inlets and power unit low voltage control lead connections. Turn system off by removing fuse or tripping circuit breaker at house fuse box.

4.Power unit shuts off during normal operation, lights on unit, wall valve and hose are all red.

4a.Debris pail and/or direct door not fully closed or attached.

4a.Check and close direct door and make sure debris pail handles are fully locked.

5.On Broan VX6000C & VX12000C units only, all lights on control panel flash when unit is first plugged in.

5a.Two or more hoses may be plugged into the system.

5a.Check all other wall inlets, utility valve at power unit and sweep inlet valve.

INTERNAL WIRING DIAGRAM

WIRING DIAGRAM VX3000C, VX6000C

WIRING DIAGRAM VX12000C

 

 

WHITE

 

 

 

 

RED

 

 

 

 

BLACK

 

 

 

BLACK

 

 

 

 

 

 

 

 

 

 

GREEN

 

 

 

GREEN

 

240 VOLTS

GREEN

 

 

120 VOLTS

GREEN

 

 

 

 

GREEN

 

 

 

 

 

 

 

 

CONTROL

 

 

THERMAL

 

CONTROL

 

 

 

 

BOARD

THERMAL

 

PROTECTOR

 

BLACK

 

 

 

BLACK

PROTECTOR

 

 

BOARD

 

 

 

 

 

 

 

 

 

 

BLACK

 

 

 

 

 

 

 

 

 

 

 

MOTOR

 

RED

 

 

BLACK

MOTOR

 

 

 

WHITE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

YELLOW

YELLOW

 

 

 

 

 

THERMAL

 

 

 

 

 

 

 

PROTECTOR

 

 

 

 

 

YELLOW

YELLOW

 

BLACK

 

 

 

 

 

MOTORGREEN

AE0005A

CONTROL

 

AE0006A

CONTROL

 

 

Page 5
Image 5
Broan VX12000C manual TROUBLESHOOTING GUIDE cont’d, Internal Wiring Diagram, Trouble, Possible Cause, Possible Remedy, page