APPENDIX A - 6
NC9100h_FM6.0
5
Netware GET from a server
You must have a Netware server on your network (running IPX/
SPX) and you must store the new firmware file in the SYS/Login
directory of the server. In this case, your PC makes the Print/Fax
server read the firmware data from the assigned Netware
server, the Print/Fax server attaches to the Netware server and
reads the firmware itself.
Reloading using the FTP Protocol from a command prompt
By specifying the Print/Fax server password as the username when
logging on, it becomes possible to upgrade the firmware of the Print/
Fax server or printer (if supported). The following example assumes
that the Print/Fax server password is cambridge
D:\>ftp
ftp> open 220.0.250.200
Connected to 220.0.250.200.
220 FTP print service:V-1.05/Use the network
password for the ID if updating.
User (220.0.250.200:(none)): cambridge
230 User cambridge logged in.
ftp> bin
200 Ready command OK.
ftp> hash
Hash mark printing on ftp: (2048 bytes/hash mark) .
ftp> send brnt261.blf
200 Ready command OK.
150 Transfer Start
#################################################
########
#################################################
#################################################
#################################################
###########################
226 Data Transfer OK/Entering FirmWareUpdate mode.
ftp: 1498053 bytes sent in 8.52Seconds
175.77Kbytes/sec.
ftp> close
226 Data Transfer OK.
ftp> quit
After sending firmware to the
machine
, do not turn off the
machine
until after the
machine
has performed an automatic
restart.