FILTRATION

For some old systems, there is a reluctance to clean the piping because of the possibility of leaks occurring in badly corroded lines. Should the customer refuse cleaning, it is necessary to install filtration equipment. Install either a fibrous filter or a centrifugal filter in the boiler return piping. This will collect and remove sediment from the system. A booster pump may have to be installed as well to overcome the additional pressure drop introduced in the line by the filter. When filling the system, provide chemical treatment as outlined in Section 3.5.

CAUTION

Failure to properly clean the system or to install mechanical sediment removal equipment can result in pipe blockage and severe corrosion plus damage to pumps, controls, and air removal devices.

3.5 BOILER WATER TREATMENT

PURPOSE OF WATER TREATMENT

Water treatment is required for satisfactory operation of the boiler system. It must be devised to prevent depositing of scale and corrosion and other such harmful elements that may be in the water supply.

A qualified water treatment chemist should be consulted and the water systematically treated.

OBJECTIVES

The basic objectives of water treatment are:

Prevent the accumulation of scale and deposits in the boiler system.

Protect the boiler against corrosion.

Maintain the highest possible boiler efficiency.

Decrease the amount of boiler system down time from cleaning.

CONTINUOUS MONITORING REQUIRED

Water treatment should be checked and maintained whenever the boiler is operating. The boiler operator should be sure that the boiler is not operating for long periods without proper water treatment.

Water treatment may vary from season to season or over a period of time. Therefore, the water treatment procedure should be checked not less than four times a year, and possibly more frequently as the local water conditions may indicate.

All water introduced into the boiler system should be softened and should include an oxygen removal system. This is required to remove dissolved oxygen from the water. Dissolved oxygen can cause severe corrosion in the heating system.

DRAINING AND REFILLING THE BOILER & SYSTEM

If the system is drained and then refilled, chemical treatment is essential to treat the make-up water. Use only clean, softened water

11

Page 15
Image 15
Bryan Boilers AH-FS151250D service manual Boiler Water Treatment

AH-FS151250D specifications

The Bryan Boilers AH-FS151250D is a compact, high-efficiency, versatile boiler designed for a wide range of applications in commercial and industrial settings. With a focus on sustainability and energy savings, this model stands out due to its innovative features and advanced technology.

One of the primary characteristics of the AH-FS151250D is its forced circulation design, which enhances the boiler's efficiency and thermal performance. This design promotes uniform heating and prevents hot spots, which can lead to failures and inefficiencies in traditional boilers. The forced circulation system ensures rapid heat transfer, making it ideal for processes requiring quick response times.

Another significant feature of the AH-FS151250D is its modular construction, allowing for easy installation and flexibility in operation. The boiler's compact footprint makes it suitable for facilities with limited space, while its modularity offers scalability. This means that users can easily expand their heating capacity by adding more units as needed.

The AH-FS151250D also boasts advanced control systems that provide precise management of operating conditions. These controls can optimize fuel use, enhance efficiency, and support a variety of fuels, including natural gas, propane, and other gaseous fuels. The integration of sophisticated automation technology helps operators maintain optimal performance while reducing operational costs.

Additionally, the Bryan Boilers AH-FS151250D incorporates advanced insulation materials that improve thermal retention and minimize energy loss. This feature contributes to the boiler's overall efficiency, further supporting sustainability efforts in industrial applications.

Durability is a hallmark of the AH-FS151250D, with a robust construction designed to withstand the rigors of continuous operation. The materials used are resistant to corrosion and high temperatures, ensuring a long lifespan with minimal maintenance requirements.

In summary, the Bryan Boilers AH-FS151250D combines efficiency, flexibility, and durability, making it an excellent choice for various commercial and industrial heating applications. Its innovative features, such as forced circulation, modular design, and advanced control technologies, position it as a leader in the boiler market, supporting users in their quest for sustainable and effective energy solutions.