6. System Operate

Induction Heater C Library User Manual Version 1.2

6. System Operate

6.1. Key & Led Definition

The system key buttons and leds are defined as below.

Error

 

Timer

 

CaoCai

 

HuoGuo

Clear

 

Timer

Inc

 

Dec

DunCai6.1. Key & Led DefinitionManual background BaoTang Manual backgroundManual background BaoWen Manual backgroundManual background Power

View

 

Power

M-Inc

 

M-Dec

Key Define

Clear---------------

Clear the timer.

Timer---------------

Set the timer.

Inc-------------------

Power increase.

Dec-----------------

Power decrease.

M-Inc---------------

Mode increase.

M-Dec--------------

Mode decrease.

View----------------

Change the display, power or timer.

Power--------------

Turn on or turn off the device.

Led Define

Error----------------

Error display.

Timer---------------

Timer display.

CaoCai-------------

Mode display.

HuoGuo-------------

Mode display.

DunCai-------------

Mode display.

BaoTang-------------

Mode display.

BaoWen-------------

Mode display.

Power----------------

Power display.

Error Code

Error Code

Description

Notes

 

 

 

0xE0

Power under voltage

 

 

 

 

0xE1

Power over voltage

 

 

 

 

0xE2

Power over current

 

 

 

 

0xE3

Main sensor over 300

 

 

 

 

0xE4

Main sensor break circuit

 

 

 

 

0xE5

Main sensor short circuit

 

 

 

 

0xE6

Main sensor temp not change

 

 

 

 

0xE7

IGBT temp over 120

 

 

 

 

0xE8

IGBT sensor break circuit

 

 

 

 

0xE9

IGBT sensor short circuit

 

 

 

 

0xF0

Kettle is empty

 

 

 

 

0xF1

 

 

 

 

 

MCU-AN-500087-E-12