Bryant 113A warranty Detailed Cooling Capacities# Continued, Tested combination

Models: 113A

1 38
Download 38 pages 62.83 Kb
Page 34
Image 34
* Tested combination.

113A

DETAILED COOLING CAPACITIES# CONTINUED

EVAPORATOR AIR

 

 

 

 

 

 

 

CONDENSER ENTERING AIR TEMPERATURES ° F (° C)

 

 

 

 

 

 

 

 

 

 

75 (23.9)

 

 

85 (29.4)

 

 

95 (35)

 

 

105 (40.6)

 

 

 

115 (46.1)

 

 

125 (51.7)

 

CFM

EWB

Capacity MBtuh

Total

Capacity MBtuh

Total

Capacity MBtuh

Total

Capacity MBtuh

 

Total

Capacity MBtuh

Total

Capacity MBtuh

Total

 

 

Sys.

 

 

Sys.

 

 

 

Sys.

 

 

 

Sys.

 

 

Sys.

 

 

Sys.

° F (° C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total

Sens‡

KW**

Total

Sens‡

KW**

Total

 

Sens‡

KW**

Total

Sens‡

 

KW**

Total

Sens‡

KW**

Total

Sens‡

KW**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

113A*A060 Outdoor Section With CAR**6034A** Indoor Section

 

 

 

 

 

 

 

 

72 (22.2)

67.80

34.89

4.35

64.83

33.80

4.80

61.64

 

32.64

5.29

58.24

31.43

 

5.83

54.52

30.11

6.41

50.31

28.65

7.04

 

67 (19.4)

62.53

43.30

4.28

59.78

42.18

4.73

56.82

 

41.00

5.22

53.69

39.76

 

5.76

50.29

38.43

6.35

46.47

36.96

6.99

1750

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63 (17.2)††

58.72

42.13

4.23

56.15

41.01

4.68

53.37

 

39.81

5.17

50.43

38.56

 

5.71

47.26

37.23

6.31

43.72

35.76

6.95

 

62 (16.7)

57.74

51.63

4.22

55.26

50.49

4.66

52.60

 

49.24

5.16

49.85

49.43

 

5.71

47.17

47.17

6.31

44.20

44.20

6.96

 

57 (13.9)

56.44

56.44

4.20

54.39

54.39

4.65

52.16

 

52.16

5.15

49.79

49.79

 

5.71

47.18

47.18

6.31

44.20

44.20

6.96

 

72 (22.2)

68.70

36.53

4.46

65.64

35.43

4.91

62.33

 

34.26

5.40

58.81

33.03

 

5.94

54.97

31.69

6.52

50.63

30.21

7.14

 

67 (19.4)

63.42

45.98

4.39

60.56

44.86

4.83

57.50

 

43.66

5.33

54.27

42.41

 

5.87

50.76

41.06

6.46

46.84

39.55

7.09

2000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63 (17.2)††

59.63

44.67

4.34

56.94

43.52

4.78

54.07

 

42.32

5.28

51.04

41.05

 

5.82

47.76

39.69

6.41

44.11

38.17

7.06

 

62 (16.7)

58.86

55.26

4.33

56.34

55.78

4.78

53.88

 

53.88

5.28

51.35

51.35

 

5.83

48.55

48.55

6.42

45.37

45.37

7.07

 

57 (13.9)

58.44

58.44

4.32

56.26

56.26

4.78

53.88

 

53.88

5.28

51.35

51.35

 

5.83

48.56

48.56

6.42

45.38

45.38

7.07

 

72 (22.2)

69.36

38.09

4.57

66.19

36.98

5.01

62.79

 

35.79

5.50

59.18

34.55

 

6.04

55.24

33.21

6.62

50.79

31.71

7.24

 

67 (19.4)

64.04

48.55

4.49

61.12

47.42

4.94

57.98

 

46.21

5.43

54.67

44.94

 

5.97

51.08

43.55

6.56

47.07

41.97

7.19

2250

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63 (17.2)††

60.27

47.08

4.44

57.52

45.93

4.89

54.56

 

44.70

5.38

51.46

43.41

 

5.92

48.11

42.01

6.51

44.39

40.42

7.16

 

62 (16.7)

60.07

60.07

4.44

57.75

57.75

4.89

55.24

 

55.24

5.39

52.57

52.57

 

5.94

49.63

49.63

6.54

46.28

46.28

7.18

 

57 (13.9)

60.07

60.07

4.44

57.75

57.75

4.89

55.25

 

55.25

5.39

52.58

52.58

 

5.94

49.64

49.64

6.54

46.28

46.28

7.18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34

COOLING INDOOR

CAPACITY

POWER

FURNACE MODEL

MODEL

 

 

 

*CAP**6024A**

1.00

1.00

 

CAP**6021A**

0.98

0.98

 

CNPH*6024A**

0.99

0.99

 

CNPV*6024A**

0.99

0.99

 

CSPH*6012A**

1.00

1.00

 

FV4BNB006

0.99

0.97

 

FX4CN(B,F)060

1.01

1.01

 

FY4ANB060

0.98

0.98

 

CAP**6021A**

0.97

0.97

315(A,J)AV060110

CSPH*6012A**

0.98

0.98

315(A,J)AV060110

CAP**6024A**

0.98

0.98

315(A,J)AV066135

CNPH*6024A**

0.97

0.96

315(A,J)AV066135

CNPV*6024A**

0.97

0.97

315(A,J)AV066135

* Tested combination.

COOLING INDOOR

CAPACITY

POWER

FURNACE MODEL

MODEL

 

 

 

CSPH*6012A**

0.98

0.97

315(A,J)AV066135

CAP**6024A**

0.98

0.97

315(A,J)AV066155

CNPH*6024A**

0.98

0.97

315(A,J)AV066155

CNPV*6024A**

0.98

0.97

315(A,J)AV066155

CSPH*6012A**

0.98

0.97

315(A,J)AV066155

CAP**6021A**

0.98

0.98

353AAV060100

CNPH*6024A**

0.98

0.98

353AAV060100

CSPH*6012A**

0.98

0.98

353AAV060100

CAP**6024A**

0.98

0.98

353AAV060120

CNPH*6024A**

0.98

0.98

353AAV060120

CNPV*6024A**

0.98

0.98

353AAV060120

CSPH*6012A**

0.98

0.98

353AAV060120

CAP**6021A**

0.97

1.01

355(A,C)AV060080

COOLING INDOOR

CAPACITY

POWER

FURNACE MODEL

MODEL

 

 

 

CAP**6021A**

0.97

0.99

355(A,C)AV060100

CAP**6024A**

0.98

0.98

355(A,C)AV060120

CAP**6021A**

0.97

0.97

313*AV048090

CNPH*6024A**

0.97

0.97

313*AV048090

CSPH*6012A**

0.97

0.97

313*AV048090

CAP**6021A**

0.97

0.96

313*AV060110

CNPH*6024A**

0.98

0.97

313*AV060110

CSPH*6012A**

0.98

0.97

313*AV060110

CAP**6024A**

0.97

0.97

313*AV060135

CNPH*6024A**

0.97

0.97

313*AV060135

CNPV*6024A**

0.97

0.97

313*AV060135

CSPH*6012A**

0.97

0.97

313*AV060135

{Total and sensible capacities are net capacities. Blower motor heat has been subtracted.

}Sensible capacities shown are based on 80_F (27_C) entering air at the indoor coil. For sensible capacities at other than 80_F (27_C), deduct 835 Btuh

(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80_F (27_C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80_F (27_C).

#Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240---94. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.

** System kw is total of indoor and outdoor unit kilowatts.

{{ At TVA rating indoor condition (75_F edb/63_F ewb). All other indoor air temperatures are at 80_F edb.

NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. EWB — Entering Wet Bulb

NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.

Page 34
Image 34
Bryant 113A warranty Detailed Cooling Capacities# Continued, Tested combination

FAQ

What are the detailed cooling capacities based on?

The detailed cooling capacities are based on indoor and outdoor units at the same elevation per ARI standard 210/240---94.

What is the system kw total based on?

The system kw is the total of indoor and outdoor unit kilowatts at TVA rating indoor condition 75°F edb/63°F ewb.

What is the importance of indoor air temperatures for the capacities?

All other indoor air temperatures are at 80°F edb. Interpolation can be performed when the required data falls between the published data. Extrapolation is not acceptable.