Bryant 113A warranty Sound Hood, Support Feet, Thermostatic Expansion Valve TXV, Time-DelayRelay

Models: 113A

1 38
Download 38 pages 62.83 Kb
Page 6
Image 6
10. Sound Hood

Accessory Description and Usage (Listed Alphabetically) (Continued)

113A

10. Sound Hood

Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dBA.

Usage Guideline:

Suggested when unit is installed closer than 15 ft (4.57 m) to quiet areas, bedrooms, etc.

Suggested when unit is installed between two houses less than 10 ft (3.05 m) apart.

11. Support Feet

Four stick-on plastic feet that raise the unit 4 in. (101.6 mm) above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion.

Usage Guideline:

Suggested in the following applications: Coastal installations.

Windy areas or where debris is normally circulating. Rooftop installations.

For improved sound ratings.

12. Thermostatic Expansion Valve (TXV)

Amodulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator.

Kit includes valve, adapter tubes, and external equalizer tube. Hard shut off types are available.

NOTE: When using a hard shut off TXV with single phase reciprocating compressors, a Compressor Start Assist Capacitor and Relay is required.

13. Time-Delay Relay

An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off.

NOTE: Most indoor unit controls include this feature. For those that do not, use the guideline below.

Usage Guideline:

For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.

14. Winter Start Control

This control is designed to alleviate nuisance opening of the low-pressure switch by bypassing it for the first 3 minutes of operation.

Usage Guideline:

Required to achieve ARI ratings in certain equipment combinations. Refer to combination ratings.

Hard shut off TXV or LLS required in air conditioner long line applications.

Required for use on all zoning systems.

6

Page 6
Image 6
Bryant 113A warranty Sound Hood, Support Feet, Thermostatic Expansion Valve TXV, Time-DelayRelay, Winter Start Control

FAQ

How does the sound hood reduce noise?

The wraparound cover for the compressor reduces the sound level by about 2 dBA.

When should support feet be used?

Support feet are suggested for coastal installations, windy areas, rooftop installations, and for improved sound ratings.

What does the thermostatic expansion valve kit include?

The kit includes the valve, adapter tubes, and an external equalizer tube.