ACCESSORY USAGE GUIDELINE

 

REQUIRED FOR LOW---AMBI-

REQUIRED FOR LONG

REQUIRED FOR

 

LINE

SEA COAST

ACCESSORY

ENT COOLING APPLICATIONS

APPLICATIONS*

APPLICATIONS

 

(Below 55°F/12.8_C)

 

(Over 80 ft./24.38 m)

(Within 2 miles/3.22 km)

 

 

Ball Bearing Fan Motor

Yes{

No

No

 

 

 

 

Compressor Start Assist Capacitor and Relay

Yes

Yes

No

Crankcase Heater

Yes

Yes

No

 

 

 

 

Evaporator Freeze Thermostat

Yes

No

No

 

 

 

 

Hard Shut---Off TXV

Yes

Yes

Yes

Liquid Line Solenoid Valve

No

No

No

 

 

 

 

Motor MasterControl or

Yes

No

No

Low---ambient Pressure Switch

 

 

 

 

 

 

 

Support Feet

Recommended

No

Recommended

Winter Start Control

Yes

No

No

*For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split---System Longline Application Guideline.

{Required for Low---Ambient Controller (full modulation feature) MotorMasterr Control.

Accessory Description and Usage (Listed Alphabetically)

1. Ball-Bearing Fan Motor

A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.

Usage Guideline:

Required on all units when MotorMasterr is used.

2. Compressor Start Assist - Capacitor and Relay

Start capacitor and relay gives a ”hard” boost to compressor motor at each start up.

Usage Guideline:

Required for reciprocating compressors in the following applications:

Long line

Low ambient cooling

Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil

Required for single-phase scroll compressors in the following applications:

Long line

Low ambient cooling

Suggested for all compressors in areas with a history of low voltage problems.

3. Compressor Start Assist — PTC Type

Solid state electrical device which gives a ”soft” boost to the compressor at each start-up.

Usage Guideline:

Suggested in installations with marginal power supply.

4. Crankcase Heater

An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging.

Usage Guideline:

Required in low ambient cooling applications. Required in long line applications.

Suggested in all commercial applications.

5. Cycle Protector

The cycle protector is designed to prevent compressor short cycling. This control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including power outage, protector control trip, thermostat jiggling, or normal cycling.

6. Evaporator Freeze Thermostat

An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze-up conditions.

Usage Guideline:

Required when low ambient kit has been added.

7. Low-Ambient Pressure Switch Kit

A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low-ambient temperatures down to 0_F (-18_C) when properly installed.

Usage Guideline:

ALow-Ambient Pressure Switch or MotorMasterr Low-Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C).

8.MotorMasterr Low-Ambient Controller

Afan-speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to -20_F (-28.9_C), it maintains condensing temperature at 100_F ±10_F (37.8_C ± 5.5_C).

Usage Guideline:

A MotorMasterr Low Ambient Controller or Low-Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C).

Suggested for all commercial applications.

9. Outdoor Air Temperature Sensor

Designed for use with Bryant Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also

is required to enable special thermostat features such as auxiliary heat lock out.

113A

Usage Guideline:

Suggested for all Bryant thermostats listed in this publication.

5

Page 5
Image 5
Bryant 113A warranty Accessory Usage Guideline

113A specifications

The Bryant 113A is a highly efficient air conditioning unit, specifically designed for residential use. A part of Bryant's esteemed line of heating and cooling solutions, the 113A stands out for its reliability, performance, and energy efficiency. It is built for homeowners seeking comfort and consistent indoor temperatures, even in extreme weather conditions.

One of the key features of the Bryant 113A is its impressive energy efficiency rating. This unit is equipped with a Seasonal Energy Efficiency Ratio (SEER) of up to 14.5, which allows consumers to save on energy bills while minimizing their environmental footprint. The 113A's energy-efficient compressor operates quietly and provides an effective cooling experience, making it suitable for both day and night use.

The Bryant 113A is designed with advanced technology that ensures optimal performance. It includes a single-stage compressor which effectively cools the indoor spaces without consuming excessive power. The unit employs a durable rust-resistant cabinet, ensuring durability and longevity even when exposed to the elements. These design elements not only enhance the system's durability but also make it visually appealing, seamlessly blending with various architectural styles.

Another significant characteristic of the Bryant 113A is its air filtration system. The unit is compatible with various air filters, which help to reduce dust, pollen, and other airborne allergens, promoting healthier indoor air quality. This feature is particularly beneficial for families with allergy sufferers, as it ensures a cleaner and more comfortable living environment.

The Bryant 113A also emphasizes easy installation and maintenance. Its compact design allows it to fit in tight spaces, while still providing robust cooling capabilities. Homeowners benefit from straightforward maintenance requirements, ensuring that the unit operates efficiently throughout its lifespan.

In conclusion, the Bryant 113A is a versatile air conditioning solution that combines efficiency, comfort, and innovative technology. With its respectable SEER rating, durable construction, advanced air filtration, and ease of maintenance, it remains a popular choice for homeowners looking to enhance their indoor climate without compromising on energy efficiency. Embracing the Bryant 113A means investing in superior comfort, reliability, and long-term savings.