Bryant manual 59000 12.50 14.50 3048424 124ANA060---C

Models: 124A

1 32
Download 32 pages 47.85 Kb
Page 19
Image 19

COMBINATION RATINGS CONTINUED

ARI Ref. No.

Model Number

Indoor Model

Furnace Model

Capacity

EER

SEER

Phase

3048398

124ANA060---C

CSPH*6012A**

313*AV060135

57500

12.20

14.50

1

3048418

124ANA060---C

CSPH*6012A**

315(A,J)AV060110

57500

12.00

14.20

1

3048419

124ANA060---C

CSPH*6012A**

315(A,J)AV066135

57500

12.00

14.50

1

3048420

124ANA060---C

CSPH*6012A**

315(A,J)AV066155

58000

12.00

14.50

1

3102128

124ANA060---C

CSPH*6012A**

353AAV048080

57000

12.00

14.00

1

3102129

124ANA060---C

CSPH*6012A**

353AAV060100

57500

12.00

14.00

1

3102130

124ANA060---C

CSPH*6012A**

353AAV060120

57500

12.20

14.50

1

3048415

124ANA060---C

CSPH*6012A**

355(A,C)AV060080

56000

12.00

14.20

1

3048416

124ANA060---C

CSPH*6012A**

355(A,C)AV060100

56000

12.00

14.50

1

3048417

124ANA060---C

CSPH*6012A**

355(A,C)AV060120

56000

12.00

14.50

1

3048414

124ANA060---C

CSPH*6012A**+TDR

 

58000

12.00

14.00

1

3048423

124ANA060---C

FE4ANB006+UI

 

59000

12.50

14.50

1

3048424

124ANA060---C

FV4BNB006

 

59000

12.50

14.50

1

3048422

124ANA060---C

FX4CN(B,F)060

 

59500

12.00

14.00

1

3048421

124ANA060---C

FY4ANB060

 

59000

11.50

13.50

1

* Tested combination

EER — Energy Efficiency Ratio

SEER — Seasonal Energy Efficiency Ratio

TDR — Time---Delay Relay. In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR.

TXV — Thermostatic Expansion Valve

NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.

2.Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures.

3.Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.

4.Do not apply with capillary tube coils as performance and reliability are significantly affected.

124A

19

Page 19
Image 19
Bryant manual 59000 12.50 14.50 3048424 124ANA060---C

124A specifications

The Bryant 124A is a highly regarded heating and cooling unit, well-known for its efficient performance and reliability in residential settings. This air conditioning and heating system is designed to provide optimal comfort throughout the year while integrating seamlessly into a variety of home environments.

One of the main features of the Bryant 124A is its efficiency rating. The system boasts a Seasonal Energy Efficiency Ratio (SEER) rating of up to 16, making it an energy-conscious choice for homeowners. This high efficiency not only helps reduce energy costs but also contributes to a smaller carbon footprint, aligning with environmentally friendly practices.

The Bryant 124A utilizes advanced ComfortHeat technology, which ensures even temperature distribution throughout the home. This feature minimizes hot and cold spots, allowing for a comfortable living space regardless of external weather conditions. The system is equipped with a variable speed compressor, which adjusts its operation based on the immediate cooling or heating demands, further enhancing its energy efficiency and reducing wear and tear on the system.

In terms of reliability, the Bryant 124A is built with high-quality materials designed to withstand the rigors of changing weather conditions. It comes with a robust cabinet that provides protection against corrosion, ensuring longevity and reducing maintenance needs over time. Additionally, it features a lightweight design for easier installation, making it suitable for both new constructions and retrofits.

An added advantage of the Bryant 124A is its compatibility with smart thermostats, enabling homeowners to control their heating and cooling systems remotely through mobile apps. This integration allows for customizable settings based on individual preferences and schedules, further enhancing energy savings.

The Bryant 124A is also designed with noise reduction technology, ensuring quieter operation compared to conventional systems. This makes it an ideal choice for homes where noise levels are a concern.

In summary, the Bryant 124A is a versatile and efficient heating and cooling system packed with advanced technologies and features designed to provide comfort and reliability. With its energy efficiency, durability, and smart integration, it stands out as a favored option for homeowners seeking a dependable climate control solution.