Bryant 124A manual Detailed Cooling CAPACITIES#

Models: 124A

1 32
Download 32 pages 47.85 Kb
Page 20
Image 20

DETAILED COOLING CAPACITIES#

124A

EVAPORATOR AIR

 

 

 

 

 

 

 

CONDENSER ENTERING AIR TEMPERATURES ° F (° C)

 

 

 

 

 

 

 

 

 

 

75 (23.9)

 

 

85 (29.4)

 

 

95 (35)

 

 

105 (40.6)

 

 

 

115 (46.1)

 

 

125 (51.7)

 

CFM

EWB

Capacity MBtuh

Total

Capacity MBtuh

Total

Capacity MBtuh

Total

Capacity MBtuh

 

Total

Capacity MBtuh

Total

Capacity MBtuh

Total Sys.

 

 

Sys.

 

 

Sys.

 

 

 

Sys.

 

 

 

Sys.

 

 

Sys.

 

 

° F (° C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW**

 

Total

Sens‡

KW**

Total

Sens‡

KW**

Total

 

Sens‡

KW**

Total

Sens‡

 

KW**

Total

Sens‡

KW**

Total

Sens‡

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

124ANA018

---C Outdoor

Section With CAP**2414A** Indoor Section

 

 

 

 

 

 

 

 

72 (22.2)

21.57

11.21

1.17

20.52

10.80

1.32

19.45

 

10.39

1.49

18.33

9.97

 

1.67

17.18

9.55

1.88

15.93

9.09

2.11

525

67 (19.4)

19.60

13.63

1.18

18.65

13.23

1.33

17.67

 

12.81

1.50

16.65

12.40

 

1.69

15.60

11.96

1.90

14.46

11.51

2.13

62 (16.7)

17.82

16.04

1.19

16.96

15.63

1.34

16.08

 

15.22

1.51

15.18

14.79

 

1.70

14.29

14.29

1.91

13.44

13.44

2.13

 

 

 

 

57 (13.9)

17.16

17.16

1.20

16.49

16.49

1.35

15.79

 

15.79

1.51

15.06

15.06

 

1.70

14.29

14.29

1.91

13.44

13.44

2.13

 

72 (22.2)

22.01

11.78

1.19

20.92

11.37

1.34

19.79

 

10.95

1.51

18.62

10.52

 

1.70

17.42

10.09

1.91

16.12

9.62

2.14

600

67 (19.4)

20.03

14.54

1.21

19.03

14.13

1.36

18.00

 

13.71

1.53

16.94

13.28

 

1.71

15.84

12.84

1.92

14.66

12.37

2.15

62 (16.7)

18.27

17.29

1.22

17.38

16.86

1.37

16.50

 

16.41

1.54

15.70

15.70

 

1.72

14.86

14.86

1.93

13.95

13.95

2.16

 

 

 

 

57 (13.9)

17.96

17.96

1.22

17.23

17.23

1.37

16.48

 

16.48

1.54

15.70

15.70

 

1.72

14.87

14.87

1.93

13.95

13.95

2.16

 

72 (22.2)

22.34

12.32

1.22

21.20

11.90

1.37

20.03

 

11.47

1.54

18.83

11.04

 

1.72

17.58

10.60

1.93

16.24

10.13

2.16

675

67 (19.4)

20.35

15.42

1.23

19.31

15.00

1.38

18.25

 

14.57

1.55

17.15

14.13

 

1.74

16.02

13.68

1.95

14.80

13.21

2.18

62 (16.7)

18.68

18.46

1.24

17.86

17.86

1.39

17.06

 

17.06

1.56

16.22

16.22

 

1.75

15.33

15.33

1.95

14.37

14.37

2.18

 

 

 

 

57 (13.9)

18.63

18.63

1.24

17.86

17.86

1.39

17.06

 

17.06

1.56

16.22

16.22

 

1.75

15.33

15.33

1.95

14.37

14.37

2.18

 

COOLING INDOOR

CAPACITY

POWER

FURNACE MODEL

 

MODEL

 

 

 

 

 

*CAP**2414A**

1.00

1.00

 

 

CAP**1814A**

0.99

1.02

 

 

CAP**2417A**

1.00

1.00

 

 

CNPF*2418A**

1.00

1.00

 

 

CNPH*2417A**

1.00

1.00

 

 

CNPV*1814A**

0.99

1.02

 

 

CNPV*2414A**

1.00

1.00

 

 

CNPV*2417A**

1.00

1.00

 

 

CSPH*2412A**

1.00

0.96

 

20

 

 

 

 

FE4ANF002

1.01

0.88

 

 

FF1ENP018

0.99

1.02

 

 

FF1ENP024

1.00

1.03

 

 

FV4BNF002

1.01

0.88

 

 

FX4CNF018

1.00

0.88

 

 

FX4CNF024

1.02

0.90

 

 

FY4ANF018

0.99

1.02

 

 

FY4ANF024

0.99

1.02

 

COOLING INDOOR

CAPACITY

POWER

FURNACE MODEL

MODEL

 

 

 

CAP**1814A**

0.98

0.90

315(A,J)AV036070

CAP**2414A**

0.99

0.88

315(A,J)AV036070

CNPH*2417A**

0.99

0.88

315(A,J)AV036070

CNPV*1814A**

0.98

0.90

315(A,J)AV036070

CNPV*2414A**

0.99

0.88

315(A,J)AV036070

CSPH*2412A**

0.99

0.88

315(A,J)AV036070

CAP**2417A**

0.99

0.88

315(A,J)AV048090

CNPH*2417A**

0.99

0.88

315(A,J)AV048090

CNPV*2417A**

0.99

0.88

315(A,J)AV048090

CSPH*2412A**

0.99

0.88

315(A,J)AV048090

CAP**2417A**

1.00

0.87

353AAV036040

CNPH*2417A**

1.00

0.88

353AAV036040

CNPV*2417A**

1.00

0.88

353AAV036040

CSPH*2412A**

1.00

0.88

353AAV036040

CAP**2417A**

1.00

0.87

353AAV036060

CNPH*2417A**

1.00

0.88

353AAV036060

CNPV*2417A**

1.00

0.88

353AAV036060

COOLING INDOOR

CAPACITY

POWER

FURNACE MODEL

MODEL

 

 

 

CSPH*2412A**

1.00

0.88

353AAV036060

CNPH*2417A**

0.99

0.88

355(A,C)AV042040

CSPH*2412A**

0.99

0.88

355(A,C)AV042040

CAP**2417A**

0.99

0.88

355(A,C)AV042060

CNPH*2417A**

0.99

0.88

355(A,C)AV042060

CNPV*2417A**

0.99

0.88

355(A,C)AV042060

CSPH*2412A**

0.99

0.88

355(A,C)AV042060

CNPH*2417A**

0.99

0.88

355(A,C)AV042080

CSPH*2412A**

0.99

0.88

355(A,C)AV042080

CAP**1814A**

1.00

0.90

313*AV024045

CAP**2414A**

1.01

0.89

313*AV024045

CNPH*2417A**

1.01

0.89

313*AV024045

CNPV*1814A**

1.00

0.90

313*AV024045

CNPV*2414A**

1.01

0.89

313*AV024045

CSPH*2412A**

1.01

0.89

313*AV024045

See notes on page 29

Page 20
Image 20
Bryant 124A manual Detailed Cooling CAPACITIES#

124A specifications

The Bryant 124A is a highly regarded heating and cooling unit, well-known for its efficient performance and reliability in residential settings. This air conditioning and heating system is designed to provide optimal comfort throughout the year while integrating seamlessly into a variety of home environments.

One of the main features of the Bryant 124A is its efficiency rating. The system boasts a Seasonal Energy Efficiency Ratio (SEER) rating of up to 16, making it an energy-conscious choice for homeowners. This high efficiency not only helps reduce energy costs but also contributes to a smaller carbon footprint, aligning with environmentally friendly practices.

The Bryant 124A utilizes advanced ComfortHeat technology, which ensures even temperature distribution throughout the home. This feature minimizes hot and cold spots, allowing for a comfortable living space regardless of external weather conditions. The system is equipped with a variable speed compressor, which adjusts its operation based on the immediate cooling or heating demands, further enhancing its energy efficiency and reducing wear and tear on the system.

In terms of reliability, the Bryant 124A is built with high-quality materials designed to withstand the rigors of changing weather conditions. It comes with a robust cabinet that provides protection against corrosion, ensuring longevity and reducing maintenance needs over time. Additionally, it features a lightweight design for easier installation, making it suitable for both new constructions and retrofits.

An added advantage of the Bryant 124A is its compatibility with smart thermostats, enabling homeowners to control their heating and cooling systems remotely through mobile apps. This integration allows for customizable settings based on individual preferences and schedules, further enhancing energy savings.

The Bryant 124A is also designed with noise reduction technology, ensuring quieter operation compared to conventional systems. This makes it an ideal choice for homes where noise levels are a concern.

In summary, the Bryant 124A is a versatile and efficient heating and cooling system packed with advanced technologies and features designed to provide comfort and reliability. With its energy efficiency, durability, and smart integration, it stands out as a favored option for homeowners seeking a dependable climate control solution.