Bryant 124A Electrical Data, A-Weightedsound Power, Charging Subcooling Txv-Typeexpansion Device

Models: 124A

1 32
Download 32 pages 47.85 Kb
Page 7
Image 7
ELECTRICAL DATA

ELECTRICAL DATA

 

 

OPER

 

 

 

 

MIN

MIN WIRE

MAX

MAX

MAX

UNIT

 

COMPR

FAN

 

WIRE

LENGTH

LENGTH

FUSE**

SIZE ---

V/PH

VOLTS*

 

 

 

MCA

SIZE{

SIZE{

ft. (m)}

ft. (m)}

or CKT

SERIES

 

 

 

 

 

 

 

 

 

 

 

BRK

 

 

MAX

MIN

LRA

RLA

FLA

 

60° C

75° C

60° C

75° C

AMPS

 

 

 

 

 

 

 

 

 

 

 

 

 

018---C

 

 

 

48.0

9.0

0.5

11.7

14

14

67 (20.4)

64 (19.5)

15

024---D

 

 

 

58.3

13.5

0.5

17.3

14

14

46 (14.0)

43 (13.1)

30

030---D

 

 

 

73.0

14.1

0.5

18.1

14

14

44 (13.4)

41 (12.5)

30

036---C

208/230/1

253

197

79.0

16.7

1.2

22.0

12

12

57 (17.4)

54 (16.5)

35

042---D

 

 

 

112.0

17.9

1.2

23.6

12

10

53 (16.2)

50 (15.2)

40

048---C

 

 

 

117.0

21.8

1.2

28.4

10

10

70 (21.3)

67 (20.4)

40

060---C

 

 

 

134.0

26.4

1.2

34.2

8

8

91 (27.7)

86 (26.2)

50

*Permissible limits of the voltage range at which the unit will operate satisfactorily

{If wire is applied at ambient greater than 30° C, consult table 310---16 of the NEC (ANSI/NFPA 70). The ampacity of non ---metallic---sheathed cable (NM), trade name ROMEX, shall be that of 60° C conditions, per the NEC (ANSI/NFPA 70) Article 336---26. If other than uncoated (no---plated), 60 or 75° C insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70).

}Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. ** Time---Delay fuse.

FLA --- Full Load Amps LRA --- Locked Rotor Amps MCA --- Minimum Circuit Amps RLA --- Rated Load Amps

NOTE: Control circuit is 24---V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection.

Complies with 2001 requirements of ASHRAE Standards 90.1

A-WEIGHTED SOUND POWER

UNIT SIZE ---

STANDARD

 

TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment)‘

 

VOLTAGE,

RATING

 

 

 

 

 

 

 

 

SERIES

(dBA)

125

250

 

500

1000

2000

4000

8000

 

 

 

 

 

 

 

 

 

 

018---C

73

56.0

60.0

 

65.0

69.0

63.0

60.0

52.5

024---D

74

51.0

60.0

 

66.5

66.5

64.0

60.0

52.5

030---D

74

53.0

62.0

 

68.5

69.0

65.5

61.0

54.0

036---C

72

52.0

62.0

 

65.5

67.5

63.0

61.0

53.5

042---D

74

60.0

65.5

 

68.5

68.5

65.0

60.0

52.5

048---C

73

59.5

63.5

 

66.5

67.5

64.0

62.0

55.5

060---C

74

55.5

64.0

 

67.0

69.0

65.0

60.0

54.5

NOTE: Tested in

accordance with ARI Standard 270---

95. (Not listed with ARI).

 

 

 

 

 

124A

CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE)

UNIT SIZE---VOLTAGE, SERIES

REQUIRED SUBCOOLING _F (_C)

 

 

 

018---

C

10 (5.6)

024---

D

10 (5.6)

030---

D

11 (6.1)

 

 

 

036---

C

10 (5.6)

042---

D

12 (6.7)

048---

C

9 (5.0)

 

 

 

060---

C

9 (5.0)

7

Page 7
Image 7
Bryant 124A manual Electrical Data, A-Weightedsound Power, Charging Subcooling Txv-Typeexpansion Device