Bryant 213A warranty Physical Data, Vapor Line Sizing and Cooling Capacity Loss

Models: 213A

1 44
Download 44 pages 21.9 Kb
Page 3
Image 3

PHYSICAL DATA

UNIT SIZE SERIES

018---E

024---C

030---D

 

036---D

042---C

048---D

060---D

Operating Weight lb (kg)

148

162

186

 

172

246

240

250

(67.13)

(73.48)

(84.37)

 

(78.02)

(111.58)

(108.86)

(113.40)

 

 

Shipping Weight lb (kg)

174

189

215

 

207

278

273

282

(78.93)

(85.73)

(97.52)

 

(93.89)

(126.10)

(123.8)

(127.91)

 

 

Compressor Type

 

 

 

 

Scroll

 

 

 

REFRIGERANT

 

 

Puron (R--- 410A)

 

 

 

Control

 

 

TXV (Puron Hard Shutoff)

 

 

Charge lb (kg)

4.89

5.50

7.45

 

6.49

8.14

11.12

11.00

(2.22)

(2.49)

(3.38)

 

(2.94)

(3.69)

(5.04)

(4.99)

 

 

Outdoor Heating Piston #

42

46

55

 

57

61

63

76

 

 

 

 

 

 

 

 

COND FAN

 

 

Propeller

Type, Direct

Drive

 

 

Air Discharge

 

 

 

Vertical

 

 

 

Air Qty (CFM)

2196

2614

2614

 

3472

3810

4046

4046

Motor HP

1/10

1/10

1/10

 

1/8

1/5

1/4

1/4

Motor RPM

1100

1100

1100

 

800

800

800

800

COND COIL

 

 

 

 

 

 

 

 

Face Area (Sq ft)

14.77

15.09

21.56

 

17.60

25.15

17.60

17.60

Fins per In.

25

20

20

 

20

20

20

20

Rows

1

1

1

 

1

1

2

2

Circuits

4

5

5

 

6

6

8

8

VALVE CONNECT. (In.) ID

 

 

 

 

 

 

 

 

Vapor

5/8

5/8

3/4

 

3/4

7/8

7/8

7/8

Liquid

 

 

 

 

3/8

 

 

 

REFRIGERANT TUBES* (In.) OD

 

 

 

 

 

 

 

 

Rated Vapor*

5/8

5/8

3/4

 

3/4

7/8

7/8

1--- 1/8

Liquid

 

 

 

 

3/8

 

 

 

*Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. Note: See unit Installation Instruction for proper installation.

VAPOR LINE SIZING AND COOLING CAPACITY LOSS

LONG LINE APPLICATION: An application is considered ”Long

when outdoor unit is above indoor unit, and up to 80 ft. (24.4 m)

line” when the total equivalent tubing length exceeds 80 ft. (24.38

when the outdoor unit is below the indoor unit. Refer to Accessory

m) or when there is more than 20 ft. (6.09 m) vertical separation

Usage Guideline below for required accessories. See Longline

between indoor and outdoor units. These applications require

Application Guideline for required piping and system

additional accessories and system modifications for reliable system

modifications. Also, refer to the table below for vapor tube

operation. The maximum allowable total equivalent length is 250

diameters based on the total length to minimize the cooling

ft. (76.2 m). The maximum vertical separation is 200 ft. (60.96 m)

capacity loss.

 

 

Maximum

 

 

 

 

Cooling Capacity Loss (%)

 

 

 

 

Unit

Vapor

 

 

 

Total Equivalent Line Length ft. (m)

 

 

 

 

Liquid

 

 

 

 

 

 

 

 

 

 

Line

Standard

 

 

 

 

 

 

 

 

Nominal

Line

 

Long Line Application Requires Accessories

 

 

Diameters

Application

 

 

 

Size (Btuh)

Diameters

 

 

 

 

 

 

 

 

(In.) OD

 

 

 

 

 

 

 

 

 

 

 

(In. OD)

26---50

51---80

81---100

101---125

126---150

151---175

176---200

201---225

226---250

 

 

 

(7.9---15.2)

(15.5---24.4)

(24.7---30.5)

(30.8---38.1)

(38.4---45.7)

(46.0---50.3)

(53.6---60.0)

(61.3---68.6)

(68.9---76.2)

 

 

 

 

 

18,000

 

1/2

1

2

3

4

6

7

8

9

10

 

1---Stage

 

 

 

 

 

 

 

 

 

 

 

 

 

5/8

0

0

1

1

1

2

2

3

3

 

Puron HP

 

 

24,000

 

5/8

0

1

1

2

3

3

4

4

5

 

1---Stage

 

 

 

 

 

 

 

 

 

 

 

 

 

3/4

0

0

0

0

1

1

1

1

1

 

Puron HP

 

 

30,000

 

5/8

1

2

3

3

4

5

6

7

8

 

1---Stage

 

3/4

0

0

1

1

1

2

2

2

3

 

Puron HP

 

7/8

0

0

0

0

1

1

1

1

1

 

36,000

 

5/8

1

2

4

5

6

7

9

10

11

 

1---Stage

3/8

3/4

0

0

1

1

2

2

3

3

4

 

Puron HP

 

7/8

0

0

0

0

1

1

1

1

2

 

42,000

 

3/4

0

1

2

2

3

4

4

5

6

 

1---Stage

 

 

 

 

 

 

 

 

 

 

 

 

 

7/8

0

0

1

1

1

2

2

2

3

 

Puron HP

 

 

48,000

 

3/4

0

1

2

3

4

5

5

6

7

 

1---Stage

 

 

 

 

 

 

 

 

 

 

 

 

 

7/8

0

0

1

1

2

2

2

3

3

 

Puron HP

 

 

60,000

 

3/4

1

2

4

5

6

7

9

10

11

 

1---Stage

 

7/8

0

1

2

2

3

4

4

5

5

 

Puron HP

 

1---1/8

0

0

0

1

1

1

1

1

1

 

Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines

 

 

 

Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit

See Long Line Applica-

 

tion Guidelines

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

213A

3

Page 3
Image 3
Bryant 213A warranty Physical Data, Vapor Line Sizing and Cooling Capacity Loss

213A specifications

The Bryant 213A is a cutting-edge system known for its impressive performance and reliability in heating and cooling applications. Designed for residential and light commercial use, it stands out due to its efficiency and innovative features, making it a popular choice among homeowners and contractors alike.

One of the main features of the Bryant 213A is its advanced two-stage cooling and heating capability. This allows for more precise temperature control and enhanced comfort. By adjusting its output based on the current demand, the unit operates at lower speeds during moderate conditions, which helps in saving energy while still maintaining desired comfort levels.

Efficiency is another hallmark of the Bryant 213A. It boasts a high Seasonal Energy Efficiency Ratio (SEER) and Energy Efficiency Ratio (EER), making it one of the most energy-efficient systems in the market. This efficiency not only contributes to lower energy bills but also helps in reducing the environmental footprint of the home, making it a greener choice for those conscious of their energy consumption.

The 213A leverages state-of-the-art technology such as a variable-speed compressor and advanced refrigerant management. This technology facilitates smooth operation and minimizes temperature fluctuations. Additionally, the unit is designed for quiet operation, which means it can efficiently cool or heat a home without intrusive noise, resulting in a more comfortable living environment.

Installation flexibility is another significant advantage of the Bryant 213A. The system is compatible with various ductwork configurations and can be easily integrated into existing HVAC systems. This adaptability makes it suitable for different home sizes and layouts, providing solutions for both new constructions and retrofits.

Durability is a core characteristic of the Bryant 213A. Crafted with high-quality materials and backed by a robust warranty, it ensures longevity and dependable performance. The unit is built to withstand various weather conditions and is designed with low maintenance in mind, further enhancing its appeal.

In conclusion, the Bryant 213A combines efficiency, advanced technology, and durability, making it an exceptional choice for heating and cooling needs. Its innovative features, quiet operation, and adaptability to different home environments set it apart in the HVAC landscape. Selecting the Bryant 213A ensures a comfortable, energy-efficient, and reliable climate control solution for any modern home.