PHYSICAL DATA

UNIT SIZE --- SERIES

018---A

024---A

030---A

036---A

042---A

048---A

060---A

Operating Weight (lb)

159

160

208

211

233

269

295

Shipping Weight (lb)

184

185

240

242

262

300

327

Compressor Type

 

 

 

Scroll

 

 

 

REFRIGERANT

 

 

Freon(R--- 22)

 

 

 

Control

 

 

TXV (R--- 22 Hard Shutoff)

 

 

 

Charge (lb)

5.5

6

7.5

8

10

14

15.5

COND FAN

 

 

Propeller Type, Direct Drive

 

 

Air Discharge

 

 

 

Vertical

 

 

 

Air Qty. (CFM)

2233

2614

2614

3334

3334

4046

4046

Motor HP

1/12

1/10

1/10

1/8

1/8

1/5

1/5

Motor RPM

800

1100

1100

800

800

800

800

COND COIL

 

 

 

 

 

 

 

Face Area (Sq. ft.)

15.09

15.09

25.87

22.63

17.6

22.63

25.15

Fins per In.

20

20

20

20

20

20

20

Rows

1

1

1

1

2

2

2

Circuits

5

6

6

6

7

8

9

VALVE CONNECT. (In. ID)

 

 

 

 

 

 

 

Vapor

5/8”

5/8”

3/4”

3/4”

7/8”

7/8”

7/8”

Liquid

 

 

 

3/8”

 

 

 

REFRIGERANT TUBES* (In. OD)

 

 

 

 

 

 

 

Vapor (0--- 80 Ft. Tube Length)

5/8”

5/8”

3/4”

3/4”

7/8”

7/8”

1--- 1/8”

Liquid (0--- 80 Ft. Tube Length)

 

 

 

3/8”

 

 

 

*For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical differential, consult the Longline Guideline. Note: See unit Installation Instruction for proper installation.

VAPOR LINE SIZING AND COOLING CAPACITY LOSS 1-STAGE HEAT PUMP APPLICATIONS

LONG LINE APPLICATION: An application is considered

 

is above indoor unit, and 60 ft. when the outdoor unit is below

”Long line” when the total equivalent tubing length exceeds 80

 

the indoor unit. Refer to Accessory Usage Guideline below for

ft. or when there is more than 20 Ft. vertical separation between

 

required accessories. See Long-Line Application Guideline for

indoor and outdoor units. These applications require additional

 

required piping and system modifications. Also, refer to the table

accessories and system modifications for reliable system

 

below for the acceptable vapor tube diameters based on the total

operation. The maximum allowable total equivalent length is 250

 

length to minimize the cooling capacity loss.

 

 

ft. The maximum vertical separation is 200 ft. when outdoor unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling Capacity Loss (%)

 

 

 

 

 

Acceptable Vapor

 

 

 

 

 

Total Equivalent Line Length (ft.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit Nominal Size (Btuh)

Line Diameter OD

Standard Application

 

 

 

 

Long Line Application

 

 

 

(in.)

 

 

 

 

Requires Accessories

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

50

80

80+

100

125

150

175

200

225

250

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18000

5/8

0

1

1

 

1

2

3

3

4

5

5

6

R---22 HP

3/4

0

0

0

 

0

0

1

1

1

1

2

2

24000

5/8

0

1

3

 

3

3

5

6

7

8

9

10

R---22 HP

3/4

0

0

0

 

0

1

1

1

2

2

3

3

30000

3/4

0

1

1

 

1

2

3

3

4

5

5

6

R---22 HP

7/8

0

0

0

 

0

1

1

1

2

2

2

3

36000

3/4

0

1

2

 

2

3

4

5

6

7

8

9

R---22 HP

7/8

0

0

1

 

1

1

2

2

3

3

4

4

42000

7/8

0

1

1

 

1

2

2

3

4

4

5

5

R---22 HP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48000

7/8

0

1

2

 

 

2

2

3

4

5

5

6

7

R---22 HP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60000

7/8

1

2

3

 

 

3

4

5

7

8

9

10

11

R---22 HP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 1/8

0

0

1

1

1

1

2

2

2

3

3

 

Standard Length = 80 ft. or less total equivalent length

Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines

Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Application Guidelines

213R

3

Page 3
Image 3
Bryant 213R warranty Physical Data, Unit Size --- Series