Bryant 213R warranty Heat Pump Heating Performance - Continued, EDB - Entering Dry Bulb

Models: 213R

1 32
Download 32 pages 61.38 Kb
Page 31
Image 31
EDB — Entering Dry Bulb

HEAT PUMP HEATING PERFORMANCE - CONTINUED

INDOOR AIR

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR COIL ENTERING AIR TEMPERATURES deg F

 

 

 

 

 

 

 

 

 

 

 

 

---3

 

 

 

7

 

 

 

17

 

 

27

 

 

37

 

 

47

 

 

57

 

 

67

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity

Total

 

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

EDB

 

CFM

MBtuh

Sys-

 

MBtuh

Sys-

MBtuh

Sys-

MBtuh

Sys-

MBtuh

Sys-

MBtuh

Sys-

MBtuh

Sys-

MBtuh

Sys-

 

 

 

Total

In-

tem

 

Total

In-

tem

Total

In-

tem

Total

In-

tem

Total

In-

tem

Total

In-

tem

Total

In-

tem

Total

In-

tem

 

 

 

teg*

KW†

 

teg*

KW†

teg*

KW†

teg*

KW†

teg*

KW†

teg*

KW†

teg*

KW†

teg*

KW†

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

213RNA060---A Outdoor Section With FC4DNF060 Indoor Section

 

 

 

 

 

 

 

 

 

 

1750

25.42

23.39

3.96

 

30.92

28.42

4.10

36.95

33.69

4.27

43.61

38.73

4.45

51.09

46.49

4.67

59.02

59.02

4.84

66.24

66.24

5.05

65.65

65.65

5.01

65

 

2000

25.81

23.75

4.00

 

31.33

28.79

4.14

37.39

34.09

4.29

44.11

39.18

4.46

51.73

47.08

4.63

58.54

58.54

4.78

61.87

61.87

4.86

59.50

59.50

4.78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2250

26.18

24.08

4.06

 

31.71

29.14

4.18

37.79

34.46

4.33

44.55

39.57

4.48

51.85

47.18

4.61

57.18

57.18

4.74

58.08

58.08

4.75

55.04

55.04

4.67

 

 

1750

24.91

22.92

4.11

 

30.49

28.02

4.28

36.53

33.30

4.46

43.11

38.29

4.65

50.48

45.93

4.87

58.78

58.78

5.06

66.16

66.16

5.29

67.06

67.06

5.30

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2000

25.31

23.28

4.16

 

30.90

28.39

4.31

36.97

33.71

4.47

43.61

38.73

4.65

51.10

46.50

4.86

58.50

58.50

5.00

63.00

63.00

5.12

61.80

61.80

5.07

 

 

2250

25.67

23.62

4.22

 

31.26

28.73

4.35

37.37

34.07

4.51

44.05

39.12

4.67

51.64

46.99

4.83

58.08

58.08

4.98

60.16

60.16

5.02

57.77

57.77

4.95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1750

24.36

22.41

4.27

 

30.00

27.57

4.45

36.07

32.89

4.64

42.61

37.85

4.85

49.92

45.43

5.08

58.19

58.19

5.31

66.02

66.02

5.54

68.87

68.87

5.63

75

 

2000

24.76

22.78

4.32

 

30.42

27.96

4.49

36.52

33.30

4.66

43.09

38.27

4.85

50.48

45.93

5.06

58.37

58.37

5.23

64.89

64.89

5.42

64.86

64.86

5.40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2250

25.13

23.12

4.38

 

30.81

28.31

4.53

36.93

33.67

4.69

43.54

38.67

4.87

51.04

46.44

5.06

58.07

58.07

5.20

61.75

61.75

5.29

60.03

60.03

5.24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating Indoor Model

Capacity

 

 

Power

 

 

Furnace Model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*FC4DN(F,B)060

 

 

1.00

 

 

1.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FK4DNB006

 

 

1.02

 

 

1.06

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAR**6024A**

 

 

1.00

 

 

1.03

 

 

315(A,J)AV066135

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CSRH*6012A**

 

 

1.01

 

 

1.02

 

 

315(A,J)AV066135

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAR**6024A**

 

 

1.00

 

 

1.02

 

 

315(A,J)AV066155

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CNRH*6024A**

 

 

1.01

 

 

1.04

 

 

315(A,J)AV066155

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CNRV*6024A**

 

 

1.01

 

 

1.04

 

 

315(A,J)AV066155

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CSRH*6012A**

 

 

1.01

 

 

1.01

 

 

315(A,J)AV066155

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.

*The Btuh heating capacity values shown are net integrated values from which the defrost effect has been subtracted. The Btuh heating from supplement heaters should be added to those values to obtain total system capacity.

{The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to obtain total system kilowatts.

EDB — Entering Dry Bulb

213R

31

Page 31
Image 31
Bryant 213R warranty Heat Pump Heating Performance - Continued, EDB - Entering Dry Bulb

FAQ

What data is included in the performance table for the Bryant 213R Heat Pump?

The performance table includes data on indoor air, outdoor coil entering air temperatures, capacity, and more.

Is interpolation acceptable when the required data falls between the published data?

Yes, interpolation may be performed when the required data falls between the published data, but extrapolation is not an acceptable practice.

What do the kW values in the note section of the article include?

The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to obtain total system kilowatts.