Bryant 213R warranty Electrical Data, A-Weightedsound Power Dba With Sound Hood

Models: 213R

1 32
Download 32 pages 61.38 Kb
Page 7
Image 7
ELECTRICAL DATA

ELECTRICAL DATA

 

 

 

 

 

 

 

 

MIN

MIN

MAX

MAX

MAX

(VOLTAGE)

 

 

 

 

 

 

 

FUSE**

 

OPER VOLTS*

COMPR

FAN

 

WIRE

WIRE

LENGTH

LENGTH

UNIT SIZE

V/PH

 

 

 

 

 

MCA

SIZE{

SIZE{

(FT)}

(FT)}

or CKT

--- SERIES

 

 

 

 

 

 

 

 

 

 

 

BRK

 

MAX

MIN

LRA

RLA

FLA

 

60° C

75° C

60° C

75° C

 

 

 

AMPS

(N) 018---A

 

 

 

41

9.0

0.5

11.70

14

14

166

158

20

(N) 024---A

 

 

 

54

11.3

0.8

14.80

14

14

131

125

25

(N) 030---A

 

 

 

72.5

14.8

0.8

19.20

12

12

161

154

30

(N) 036---A

208/230/1

253

187

88

17.0

0.9

22.10

12

12

140

133

35

(N) 042---A

 

 

 

104

21.2

0.9

27.40

10

10

181

172

40

(N) 048---A

 

 

 

137

21.2

1.2

27.60

10

10

179

170

40

(N) 060---A

 

 

 

148

28.9

1.2

37.30

8

8

207

197

60

(P) 030---A

 

 

 

63

10.4

0.75

13.75

14

14

66

63

20

(P) 036---A

 

 

 

77

11.3

0.9

15.03

12

12

96

92

25

(P) 042---A

208/230/3

253

197

88

13.4

0.9

17.65

12

12

82

78

25

(P) 048---A

 

 

 

91

13.78

1.2

18.43

10

10

125

119

30

(P) 060---A

 

 

 

123

18.7

1.2

24.58

8

10

146

89

35

(E) 036---A

 

 

 

39

5.5

0.5

7.38

14

14

247

235

15

(E) 042---A

460/3

506

414

44

6.4

0.5

8.50

14

14

214

203

15

(E) 048---A

46

7.1

0.6

9.41

14

14

193

184

15

 

 

 

(E) 060---A

 

 

 

62

8.6

0.6

11.35

14

14

160

152

15

* Permissible limits of the voltage range at which the unit will operate satisfactorily

{If wire is applied at ambient greater than 30° C (86° F), consult table 310---16 of the NEC (ANSI/NFPA 70). The ampacity of non ---metallic---sheathed cable (NM), trade name ROMEX, shall be that of 60° C (140° F) conditions, per the NEC (ANSI/NFPA 70) Article 336---26. If other than uncoated (no---plated), 60

or 75° C (140 or 167° C) insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70).

}Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. ** Time---Delay fuse.

FLA

--- Full Load Amps

LRA

--- Locked Rotor Amps

MCA

--- Minimum Circuit Amps

RLA

--- Rated Load Amps

NOTE: Control circuit is 24---V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection.

A-WEIGHTED SOUND POWER (DBA)

UNIT SIZE --- SERIES

STANDARD

TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)

RATING

125

250

500

1000

2000

4000

8000

 

018---A

75

52

59.5

64.5

71

67

61.5

54.5

024---A

76

52.5

63.5

69.5

72

67.5

64.5

59.5

030---A

76

52

64

70

71

68

66.5

65

036---A

76

53

69

66.5

69.5

66.5

63.5

62

042---A

76

57

65

68

72.5

67.5

64

59

048---A

76

57.5

65

68

70.5

69

64

60.5

060---A

77

61

62.5

70

72.5

70

67

60

A-WEIGHTED SOUND POWER (DBA) WITH SOUND HOOD

UNIT SIZE --- SERIES

STANDARD

TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)

RATING

125

250

500

1000

2000

4000

8000

 

018---A

74

52.0

59.5

64.0

68.0

64.0

60.0

52.5

024---A

75

53.5

63.0

69.0

70.5

66.5

64.0

58.5

030---A

75

53.0

64.5

69.5

70.5

67.5

64.5

60.5

036---A

75

54.0

68.5

65.5

68.0

65.0

62.0

57.5

042---A

76

58.0

64.5

67.0

71.0

65.5

61.0

54.5

048---A

75

58.0

64.0

68.0

69.0

65.5

60.5

55.5

060---A

75

59.5

61.5

67.5

70.0

68.0

64.0

57.5

CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE)

UNIT SIZE---SERIES

REQUIRED SUBCOOLING (_F)

018---A

11

024---A

11

030---A

9

036---A

11

042---A

13

048---A

13

060---A

11

213R

7

Page 7
Image 7
Bryant 213R Electrical Data, A-Weightedsound Power Dba With Sound Hood, Charging Subcooling Txv-Typeexpansion Device

FAQ

What is the required subcooling for the 036---A unit?

The required subcooling for the 036---A unit is 11°F.

What is the full load amps (FLA) for the N 048---A unit?

The FLA for the N 048---A unit is 21.2.

What is the voltage range at which the unit operates satisfactorily?

The permissible limits of the voltage range at which the unit operates satisfactorily can be found for each unit in the table.