Technical data

Introduction

 

Mechanical values

 

 

 

 

 

Width

431 mm

 

 

 

 

Depth

686 mm

 

 

 

 

Height

87 mm (2 HU)

 

 

 

 

Installation depth in the

651 mm

 

rack

 

 

 

 

 

Cable depth in the rack

200.0 mm (1000 mm rack recommended)

 

 

 

 

Weight

Approx. 24 - 27 kg (depending on configuration).

Ventilation clearance

At least 200 mm on the front and rear.

Ambient conditions

Environment class 3K2

EN 60721 / IEC 721 Part 3-3

Environment class 2K2

EN 60721 / IEC 721 Part 3-2

 

 

Temperature:

 

Operation (3K2)

10 °C ... 35 °C

Transport (2K2)

-25 °C ... 60 °C

 

 

Humidity

10% ... 85%

 

 

Condensation during operation must be avoided!

Noise level

Sound power level LWAd (ISO 9296)

< 6.6

B (standby)

 

< 7.3

B (operation)

 

 

Sound pressure level at adjacent workstation

< 49 dB (A) (standby)

LpAm (ISO 9296)

< 56 dB (A) (operation)