Fujitsu RX330 manual Installation in 3rd party racks, Racks with installation depth of 735 mm

Models: RX330

1 94
Download 94 pages 12.15 Kb
Page 42
Image 42

Installing/removing the server in/from the rack

Hardware installation

4.2.2Installation in 3rd party racks

The following parts are required to install the server in 3rd party racks:

One left and one right telescopic rail (assembled)

M5x10 screws with integrated plugwashers

I– Or, M5x10 screws with separate plugwashers can also be used. In this case, two plugwashers each must be fitted beforehand on the support uprights and the support bracket.

The descriptions and figures in this section refer to the current variable support.

ÊRefer to the manual from the rack manufacturer for details of the mechanical installation and the climatic conditions.

VCAUTION!

For installation in 3rd party racks, it must be ensured that an air flow from the front to the back of the rack is guaranteed.

ÊFit the required original parts (support bracket or cable management system).

IUnder certain circumstances, you will not be able to use some of the parts from the rack installation kit supplied - you will need to use original 3rd party rack parts instead.

ÊRemove the outer telescopic rail as described in page 40 (figure 4).

Racks with installation depth of 735 mm

The lengths of the telescopic rails do not need to be adjusted with respect to each other for the installation in rack systems with 735 mm installation depth.

ÊSecure the telescopic rails as described in section “Installation in PRIME- CENTER/DataCenter Rack” on page 39.

ÊMount the server (see section “Inserting the server” on page 43) and route the cables as described in the rack manual.

42

Operating manual

RX330 S1

Page 42
Image 42
Fujitsu RX330 manual Installation in 3rd party racks, Racks with installation depth of 735 mm