Fujitsu RX330 manual Connecting the server to the mains

Models: RX330

1 94
Download 94 pages 12.15 Kb
Page 47
Image 47

Hardware installation

Connecting the server to the mains

4.4Connecting the server to the mains

In its basic configuration level the server has a hot-plug power supply unit. A second hot plug power supply unit can be added to achieve redundant power supply. If a defect occurs in one power supply unit, the other power supply unit ensures continued operation of the server.

VCAUTION!

The installed power supply units automatically set themselves to a mains voltage in the range of 100 V - 127 V or 200 V - 240 V. Make sure that your local mains voltage is within the correct range.

2

1

Figure 10: Connecting the server to the mains

ÊConnect the power cable with the insulated connector (1) to the power supply unit of the server, and plug the power plug (2) into a grounded outlet on the mains socket strip on the rack (see the technical manual for the rack).

IA phase redundancy in the power supply of the server can be set up if two hot plug power supply units are installed.

In this case, the two power supply units are connected to two different phases.

RX330 S1

Operating manual

47

Page 47
Image 47
Fujitsu RX330 manual Connecting the server to the mains