Hardware installation Installing/removing the server in/from the rack

4.2.1Installation in PRIMECENTER/DataCenter Rack

For installation in a PRIMECENTER/DataCenter Rack, the following parts are required:

Support bracket

One left and one right telescopic rail (assembled)

M5x10 screws with integrated plugwashers

I– Or, M5x10 screws with separate plugwashers can also be used. In this case, two plugwashers each must be fitted beforehand on the support uprights and the support bracket.

The descriptions and figures in this section refer to the current variable support.

General information is provided in the Technical Manual for the PRIMECENTER and/or DataCenter Rack (see “Literature” on page 87).

When mounting the left telescopic rail in the PRIMECENTER/DataCenter Rack, the supplied support bracket must first be mounted on the rear left support upright flush with the bottom edge of the device.

2

1

Figure 3: Fitting the support bracket

ÊPosition the support bracket at the corresponding height on the rear left support upright, (insert lug in corresponding hole) (1).

ÊSecure the bracket with two screws incl. plug washers (2).

RX330 S1

Operating manual

39

Page 39
Image 39
Fujitsu RX330 manual Installation in PRIMECENTER/DataCenter Rack, Fitting the support bracket