Bryant 353AAV manual Ft M, IN. mm, 2001 to, 610 to

Models: 353AAV

1 22
Download 22 pages 30.3 Kb
Page 13
Image 13

COMBUSTION-AIR AND VENT PIPING FOR DIRECT VENT/2-PIPE (ALL SIZES) AND NON-DIRECT VENT/1-PIPE (SIZES 040 THROUGH 120 ONLY) APPLICATIONS

 

 

 

 

NON-DIRECT

 

 

 

 

 

 

ALTITUDE

UNIT SIZE

DIRECT VENT (2-PIPE) ONLY

VENT (1-PIPE)

 

NUMBER OF 90° ELBOWS

 

 

 

ONLY

 

 

 

 

 

 

FT (M)

(BTUH)

 

 

 

 

 

 

 

 

 

TERMINATION

PIPE DIA

PIPE DIA

1

2

3

4

5

6

 

 

 

 

TYPE

IN. (mm)*

IN. (mm)*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 (25)

1 (25)

5

NA

NA

NA

NA

NA

 

 

 

(1.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40,000

2 Pipe or 2-in

1-1/2 (38)

1-1/2 (38)

70

70

65

60

60

55

 

Concentric

(21.3)

(21.3)

(19.8)

(18.3)

(18.3)

(16.8)

 

 

 

 

 

 

 

2 (51)

2 (51)

70

70

70

70

70

70

 

 

 

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-1/2 (38)

1-1/2 (38)

20

15

10

5

NA

NA

 

 

2 Pipe or 2-in

(6.1)

(4.6)

(3.0)

(1.5)

 

60,000

 

 

 

 

 

Concentric

 

 

 

 

 

 

 

 

 

2 (51)

2 (51)

70

70

70

70

70

70

 

 

 

 

 

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-1/2 (38)

1-1/2 (38)

10

NA

NA

NA

NA

NA

 

 

 

(3.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80,000

2 Pipe or 2-in

2 (51)

2 (51)

55

50

35

30

30

20

0 to 2000

Concentric

(16.8)

(15.2)

(10.7)

(9.1)

(9.1)

(6.1)

 

 

 

(0 to 610)

 

 

2-1/2 (64)

2-1/2 (64)

70

70

70

70

70

70

 

 

 

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 (51)

2 (51)

5

NA

NA

NA

NA

NA

 

 

 

(1.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100,000

2 Pipe or 3-in

2-1/2 (64)

2-1/2 (64)

40

30

20

20

10

NA

 

Concentric

(12.2)

(9.1)

(6.1)

(6.1)

(3.0)

 

 

 

 

 

 

 

 

3 (76)

3 (76)

70

70

70

70

70

70

 

 

 

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-1/2 (64)

2-1/2 (64)

10

NA

NA

NA

NA

NA

 

 

 

one disk

(3.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120,000

2 Pipe or 3-in.

3 (76)†

NA

45

40

35

30

25

20

 

Concentric

(13.7)

(12.2)

(10.7)

(9.1)

(7.6)

(6.1)

 

 

 

 

 

 

 

3 (76) † no disk

3 (76)†

70

70

70

70

70

70

 

 

 

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIRECT VENT (2-PIPE) ONLY

NON-DIRECT

 

NUMBER OF 90° ELBOWS

 

ALTITUDE

UNIT SIZE

VENT (1-PIPE)

 

 

 

 

ONLY

 

 

 

 

 

 

FT (M)

(BTUH)

 

 

 

 

 

 

 

 

 

TERMINATION

PIPE DIA

PIPE DIA

1

2

3

4

5

6

 

 

 

 

TYPE

IN. (mm)*

IN. (mm)*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-1/2 (38)

1-1/2 (38)

67

62

57

52

52

47

 

 

2 Pipe or 2-in

(20.4)

(18.9)

(17.4)

(15.8)

(15.8)

(14.3)

 

40,000

 

 

 

Concentric

 

 

 

 

 

 

 

 

 

2 (51)

2 (51)

70

70

70

70

70

70

 

 

 

 

 

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-1/2 (38)

1-1/2 (38)

17

12

7

NA

NA

NA

 

 

2 Pipe or 2-in

(5.2)

(3.7)

(2.1)

 

60,000

 

 

 

 

 

 

Concentric

 

 

 

 

 

 

 

 

 

2 (51)

2 (51)

70

67

66

61

61

61

 

 

 

 

 

(21.3)

(20.4)

(20.1)

(18.6)

(18.6)

(18.6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 (51)

2 (51)

49

44

30

25

25

15

 

 

2 Pipe or 2-in

(14.9)

(13.4)

(9.1)

(7.6)

(7.6)

(4.6)

 

80,000

 

 

 

Concentric

2-1/2 (64)

2-1/2 (64)

70

70

70

70

70

70

 

 

2001 to 3000

 

 

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

 

 

 

 

(610 to 914)

 

 

 

 

 

 

 

 

 

 

 

 

2-1/2 (64)

2-1/2 (64)

35

26

16

16

6

NA

 

 

2 Pipe or 3-in

(10.7)

(7.9)

(4.9)

(4.9)

(1.8)

 

100,000

 

 

 

 

Concentric

 

 

 

 

 

 

 

 

 

3 (76)

3 (76)

70

70

70

70

66

61

 

 

 

 

 

(21.3)

(21.3)

(21.3)

(21.3)

(20.1)

(18.6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 (76)

NA

14

9

NA

NA

NA

NA

 

 

 

(4.3)

(2.7)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NA

3 (76)†

63

62

62

61

61

61

 

 

2 Pipe or 3-in.

(19.2)

(18.9)

(18.9)

(18.6)

(18.6)

(18.6)

 

120,000

 

 

 

Concentric

 

 

 

 

 

 

 

 

 

3 (76)† no disk

NA

70

70

63

56

50

43

 

 

 

 

 

(21.3)

(21.3)

(19.2)

(17.1)

(15.2)

(13.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 (102)† no

4 (102)† no disk

70

70

70

70

70

70

 

 

 

disk

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See notes at end of table.

353AAV

13

Page 13
Image 13
Bryant 353AAV manual Ft M, IN. mm, 2001 to, 610 to

353AAV specifications

The Bryant 353AAV is a high-efficiency, two-stage gas furnace designed to provide consistent heating and energy savings for residential spaces. With its advanced technology and robust features, the 353AAV is an ideal choice for homeowners looking to enhance their comfort while minimizing energy costs.

One of the main features of the Bryant 353AAV is its two-stage heating capability. This technology allows the furnace to operate at a lower, more efficient capacity most of the time, which not only enhances comfort by reducing temperature fluctuations but also decreases energy consumption. During peak demand, the unit can ramp up to a higher output, ensuring quick warmth when necessary.

Equipped with a variable-speed blower motor, the Bryant 353AAV improves airflow and overall system efficiency. This motor adjusts the speed based on the heating needs of the home, providing steady, even distribution of warm air. This feature reduces noise levels typically associated with traditional furnaces and enhances overall comfort by minimizing hot and cold spots.

The 353AAV also boasts an impressive Annual Fuel Utilization Efficiency (AFUE) rating, often exceeding 90%. This high AFUE indicates that a significant portion of fuel is converted into usable heat, making it an environmentally-friendly option that also saves homeowners money on utility bills. Additionally, this model is compatible with smart thermostat technology, allowing for easy and efficient climate control through mobile devices.

Durability and reliability are also key characteristics of the Bryant 353AAV. The furnace is constructed with high-quality materials, including a corrosion-resistant heat exchanger and a sturdy cabinet designed to withstand the test of time. Bryant backs the 353AAV with a 10-year limited warranty on parts, providing peace of mind for homeowners.

Finally, the Bryant 353AAV is designed with quiet operation in mind. Features like the insulated cabinet and noise-reducing blower motor contribute to a quieter home environment, making this model ideal for families and those sensitive to noise.

In summary, the Bryant 353AAV combines energy efficiency, advanced technology, and robust construction to offer homeowners a reliable heating solution. With its two-stage heating, variable-speed blower motor, high AFUE rating, and quiet operation, this gas furnace stands out as a top choice in residential heating systems.