Bryant 353AAV manual Downflow Subbase Dimensions IN. MM, Ment

Models: 353AAV

1 22
Download 22 pages 30.3 Kb
Page 8
Image 8

DOWNFLOW SUBBASE DIMENSIONS - IN. (MM)

 

 

 

 

 

 

 

 

 

PLENUM OPENING

FLOOR OPENING

HOLE NO.

FURNACE

 

FOR

CASING

FURNACE IN DOWNFLOW APPLICATION

 

 

 

 

WIDTH

WIDTH

 

A

B

C

D

ADJUST---

 

 

MENT

 

 

 

 

 

 

17-1/2

Furnace with or without Cased Coil Assembly or

15---1/8

19

16-3/4

20---3/8

3

(445)

Coil Box

(384)

(483)

(425)

(518)

 

21

Furnace with or without Cased Coil Assembly or

18---5/8

19

20---1/4

20---3/8

2

(533)

Coil Box

(473)

(483)

(514)

(518)

 

24-1/2

Furnace with or without Cased Coil Assembly or

22-1/8

19 (483)

23-3/4

20---3/8

1

(622)

Coil Box

(562)

(603)

(518)

 

 

353AAV

*The plenum should be constructed 1/4---in. (6 mm) smaller in width and depth than the plenum dimensions shown above.

 

 

LOCATING

 

 

TAB

 

1 1/4″ (32 μμ) TYP

 

 

PLENUM

 

 

OPENING

B

 

 

A

 

D

 

 

LOCATING

 

 

TAB

FACTORY-SUPPLIED

C

 

FIELD-INSTALLED

 

 

INSULATION

 

 

1

2

3

4

3

2

1

4

COMBUSTION-AIR PIPE FOR NON-DIRECT VENT (1-PIPE) APPLICATION

(SIZES 040 THROUGH 120 ONLY)

FIELD-SUPPLIED

 

2-IN. (51 mm) DIA.

FIELD-SUPPLIED

PVC 90° ELBOW

2-IN. (51 mm) DIA.

 

 

 

PVC PIPE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

COMBUSTION-AIR DISC

 

 

 

(FACTORY-SUPPLIED IN

 

A96211

LOOSE PARTS BAG)

 

LENGTH OF STRAIGHT

PIPE PORTION OF COMBUSTION AIR INLET PIPE ASSEMBLY - IN. (mm)

CASING WIDTH

A

 

 

 

 

17-1/2 (445 mm)

8-1/2 ± 1/2 (216 ± 13 mm)

 

 

 

21 (533 mm)

10-1/2 ± 1/2 (267 ± 13 mm)

 

 

 

24-1/2 (622 mm)

12 ± 1/2 (305 ± 13 mm)

 

 

 

CONCENTRIC VENT FOR DIRECT VENT (2-PIPE) APPLICATION (ALL MODEL SIZES)

B IN. (MM) DIA PVC

VENT/EXHAUST

13/16 (30 mm)

11/2

(38 mm)

F

E

C IN. (MM) DIA

D

A

B IN. (MM) DIA PVC

INTAKE/COMBUSTION AIR

KIT PART NO.

 

A*

B

 

C

 

D{

 

E

 

F

KGAVT0701CVT

33---

3/8 (848)

2 (51)

3

---1/2 (89)

16---

5/8 (422)

6---

1/4 (159)

5---

3/4 (146)

KGAVT0801CVT

38---

7/8 (987)

3 (76)

4---

1/2 (114)

21---

1/8 (537)

7---

3/8 (187)

6---

1/2 (165)

*Dimension A will change accordingly as Dimension D is lengthened or shortened.

{Dimension D may be lengthened to 60---in. (1524 mm) maximum. Dimension D may also be shortened by cutting the pipes provided in the kit to 12--- in. (305 mm) minimum.

8

Page 8
Image 8
Bryant 353AAV manual Downflow Subbase Dimensions IN. MM, Ment