Bryant 363AAP 361AAN manual MODEL 362AAN LOW-BOYOIL FURNACE, Features

Models: 363AAP 361AAN

1 8
Download 8 pages 30.3 Kb
Page 4
Image 4
MODEL 362AAN LOW-BOY OIL FURNACE

MODEL 362AAN LOW-BOY OIL FURNACE

The 362AAN Furnace is designed for top performance to provide years of reli- able, comfortable home heating.

The 362AAN is a Low-Boy style oil furnace that can be installed in limited over- head areas for greater application coverage. The heat exchanger is backed by a Limited Lifetime Warranty.

FEATURES

LOW-BOY CABINET STYLE—The 362AAN allows easy installation in low over- head areas such as crawlspaces and sub-basements.

HEAT EXCHANGER—The stainless steel primary and aluminized steel second- ary heat exchangers are designed for outstanding reliability backed by a Limited Lifetime Warranty. The heat exchanger utilizes crimped seams instead of welds for corrosion resistance. All internal surfaces are accessible for any field mainte- nance without removing the heat exchanger.

CLEANOUT PORTS—Allow easy cleaning of secondary heat exchanger tubes without disassembly of the furnace or heat exchanger.

CONTROLS—The Beckett oil burner is equipped with an electronic primary relay for added reliability. Integrated fan timer control board with low-voltage terminal strip and 40-va transformer make air conditioning installation easy.

HEAVY DUTY BLOWER—Blower motors are PSC type and 3 speed. The direct- drive blowers eliminate belt adjustments in the field. The constant low-speed blower switch provides air circulation during “off” cycles for indoor air filtration. DURABLE CABINET—The casing is constructed of prepainted steel for years of attractiveness. Filter provided with each furnace.

A96358

UNIT SIZE

 

036105

048125

060155

RATINGS AND PERFORMANCE

 

 

 

 

Firing Rate

 

0.76

0.90

1.12

Input (Btuh)

 

105,000

125,000

154,000

Heating Capacity (Btuh)*

 

85,000

100,000

125,000

AFUE %*

ICS

80.3

82.5

81.0

Oil Pump Stages

 

 

1

 

Heating Temperature Rise °F

 

 

55—85

 

Recommended Heating Blower Speed

 

Medium

Medium

High

Cooling CFM @ 0.5-in. wc Static Pressure

 

1550

1630

1800

Heating CFM @ 0.2-in. wc Static Pressure

 

1335

1675

1960

ELECTRICAL

 

 

 

 

Unit Volts—Hertz—Phase

 

 

115—60—1

 

Operating Voltage Range†

 

 

104—127

 

Rated Load Amps

 

12.55

15.65

16.15

Minimum Ampacity for Wire Sizing

 

14

18

19

Minimum Wire Size AWG

 

14

12

12

Maximum Wire Length (Ft)‡

 

26

32

30

Maximum Fuse Size (Amps)**

 

15

20

20

Control Transformer (24v)

 

 

40va

 

External Control Power Available

Heating

 

35va

 

 

 

 

 

 

 

Cooling

 

35va

 

Burner Model (3450 RPM)

 

 

Beckett AFG

 

BLOWER DATA

 

 

 

 

Motor HP

 

1/3

1/2

3/4

Blower Wheel Size (In.)

 

12 x 9

12 x 9

12 x 12

Blower Motor Speed and Type

 

 

1075 PSC Direct

 

Filter Quantity and Size

 

 

(1) 21-1/4 x 21-1/4 x 1

 

*Capacity and AFUE in accordance with U.S. Government DOE test procedures.

Permissible limits of the voltage range at which the unit will operate satisfactorily.

Length shown is measured 1 way along wire path between unit and service panel for maximum 2% voltage drop. ** Time-delay fuse is recommended.

ICS—Isolated Combustion System

—4—

Page 4
Image 4