Bryant 369RAN Dimensions In, DimensionalDrawing, Introduction, Location I. General

Models: 369RAN

1 12
Download 12 pages 45.88 Kb
Page 2
Image 2
DIMENSIONS (IN.)

A

TOP KNOCK-OUT FOR J DIAM VENT

1920

Fig. 2—Dimensional Drawing 3INTRODUCTION E

G LOCATIONManual background

KNOCK-OUT BOTH SIDES

FOR J DIAM VENT

19

B

L

 

VENT CONN

 

OIL INLET

 

(BOTH SIDES)

H

ELECTRICAL

 

CONNECTIONS

 

(BOTH SIDES)

 

.88 DIAM TYP

F

 

K

 

PULL

C

2

D

20

 

 

 

 

 

 

 

 

 

 

 

 

A98037

 

 

 

 

DIMENSIONS (IN.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT SIZE

A

B

C

D

E

 

F

G

H

J

K

L

036105

35

48-3/4

30-1/4

16-5/8

20

 

22

12

14

5

1-1/2

1-3/4

060120

39-1/2

53

32-1/4

18-3/4

24

 

28

12-9/32

16

6

1-5/8

1-1/2

Fig. 2—Dimensional Drawing

Understand the signal words DANGER, WARNING, and CAU- TION. These words are used with the safety-alert symbol. DAN- GER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies a hazard which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage.

INTRODUCTION

The model 369RAN Furnaces are available in 2 sizes. Each size unit is capable of 3 heat/airflow combinations by a simple nozzle change. Unit 036105 covers inputs of 70,000, 91,000, and 105,000 Btuh, and unit 060120 covers inputs of 119,000, 140,000 and 154,000 Btuh. This eliminates the need to stock 6 separate units

This furnace is a multipoise unit. It may be installed in the upflow, downflow or horizontal configuration.

The furnace is shipped as a packaged unit, complete with burner and controls. It requires a line voltage (115 vac) connection to control box, a thermostat hook-up as shown on wiring diagram, oil line connection(s), adequate duct work, and connection to a properly sized vent.

The air handling capacity of this furnace is designed for cooling airflow. Refer to Table 12 for expected airflows at various external duct static pressures.

LOCATION

I. GENERAL

WARNING: This furnace is not water tight and is not designed for outdoor installation. This furnace shall be installed in such a manner as to protect electrical com- ponents from water. Outdoor installation would lead to a hazardous electrical condition and to premature furnace failure.

WARNING: Do not use this furnace as a construction heater. Use of this furnace as a construction heater exposes furnace to abnormal conditions, contaminated combustion air, and lack of air filters. Failure to follow this warning can lead to premature furnace failure and/or vent failure which could result in a fire hazard and/or bodily harm.