21

LEGEND

AHA

Ð

Adjustable Heat

QT

Ð

Quadruple Terminal

 

 

Anticipator

RS

Ð

Rollout Switch

BR

Ð

Blower Relay

TRAN

Ð

Transformer

CÐ Contactor

CAP

Ð

Capacitor

Field Splice

COMP

Ð

Compressor Motor

 

CR

Ð

Combustion Relay

Terminal (Marked)

EQUIP

Ð

Equipment

Terminal

FS

Ð

Flame Sensor

FU

Ð

Fuse

(Unmarked)

GND

Ð

Ground

Splice

GVR

Ð

Gas Valve Relay

 

HS

Ð

Hall Effect Sensor

Splice (Marked)

HV

Ð

High Voltage

 

 

 

Transformer

Factory Wiring

TRAN

Ð

Transformer

Field Control Wiring

I

Ð

Ignitor

IDM

Ð

Induced-Draft Motor

Field Power Wiring

IFM

Ð

Indoor-Fan Motor

Accessory or

IGC

Ð

Integrated Gas Unit

Optional Wiring

 

 

Controller

LS

Ð

Limit Switch

To Indicate Common

MGV

Ð

Main Gas Valve

Potential Only, Not

NEC

Ð

National Electrical

to Represent Wiring

 

 

Code

 

OFM

Ð

Outdoor-Fan Motor

 

NOTES:

1.If any of the original wires furnished are replaced, it must be replaced with type 90 degree C wire or its equivalent.

2.See Trade Prices for thermostat and subbases.

3.Use 75 degree C copper conductors for ®eld installation.

4.For high speed IFM, disconnect RED wire from IGC terminal BM and connect BLK wire from IFM. For medium speed, disconnect RED wire from IGC terminal BM and connect BLU wire from IFM.

5.Models 583A sizes 024-036 have LS1 and LS2 wired in series. Models 583A sizes 042-060 have LS1 only.

TYPICAL WIRING SCHEMATIC Ð 208/230-1-60 SHOWN

Page 21
Image 21
Bryant 583A manual Typical Wiring Schematic Ð 208/230-1-60 Shown, Ofm

583A specifications

The Bryant 583A is a cutting-edge gas furnace designed for both efficiency and comfort, making it an ideal heating solution for residential applications. This model is particularly known for its exceptional performance and innovative technology, resulting in lower energy bills and a more consistent indoor environment.

One of the standout features of the Bryant 583A is its high-efficiency operation, boasting an AFUE (Annual Fuel Utilization Efficiency) rating of up to 95%. This means that a significant portion of the fuel consumed is converted into usable heat, making it an environmentally friendly choice that reduces energy waste. The design employs a two-stage heating operation, which allows the furnace to adjust its output according to the heating demands of the home, providing balanced warmth while minimizing energy consumption.

Built with advanced technology, the Bryant 583A includes a variable-speed blower motor that enhances comfort by distributing heated air more evenly throughout the home. This feature not only improves air circulation but also promotes quieter operation compared to standard single-speed blowers. The intelligent control system of the furnace permits compatibility with smart thermostats, which further enhances energy efficiency and user convenience.

Another notable characteristic of the Bryant 583A is its durability. Constructed with high-quality materials, this furnace is designed to withstand the rigors of continuous operation and to provide reliable service throughout its lifespan. Additionally, it features a heavy-duty heat exchanger that ensures optimal heat transfer while reducing the risk of breakdowns.

The Bryant 583A also prioritizes safety with features such as an automatic shut-off, which activates in the event of a malfunction, protecting both the system and the home. Additionally, its compact design allows for easy installation in a variety of spaces, making it a versatile choice for different home layouts.

In summary, the Bryant 583A is a remarkable gas furnace that combines high-efficiency performance, cutting-edge technology, and reliability. With its two-stage heating operation, variable-speed blower motor, and robust safety features, it caters to homeowners seeking both comfort and cost savings during the colder months. As a trusted name in heating solutions, Bryant continues to lead the way in delivering products that enhance home comfort while prioritizing energy efficiency and durability.