OPTIONS AND ACCESSORIES

FACTORY-INSTALLED OPTIONS

Louvered Grille provides hail and vandalism protection. See model number nomenclature for louvered grille options.

Coil Options include copper/copper and vinyl-coated construc- tion for refrigerant coils. Units are shipped standard with copper tube/aluminum ®n construction. See model number nomencla- ture for coil options.

FIELD-INSTALLED ACCESSORIES

Economizer with Solid-State Controls and Barometric Relief Dampers

Manual Air Damper (25% open)

Filter Rack

Flat Roof Curbs (8-in. and 14-in.)

Square-to-Round Duct Transition Kit

Thermostats

Controls Upgrade Kit

Crankcase Heater

Compressor Hard Start Kit (for use on single-phase units only)

LP Conversion Kit

High Altitude Kit

Low NOx Kit

Low Ambient Kit (Motormaster II Control)

Solid-State Time Guard II Device

Duct Conversion Kit (Horizontal to Vertical)

Economizer with Solid-State Controls and Barometric Re- lief Dampers includes ®lter racks and provide outdoor air during cooling and reduce compressor operation.

Manual Outside Air Damper includes hood and ®lter rack with adjustable damper blade for up to 25% outdoor air.

Flat Roof Curbs in both 8 in. and 14 in. sizes are available for roof mounted applications.

Square-to-Round Duct Transition Kit enables 024-048 size units to be ®tted to 14 in. round ductwork.

Compressor Hard Start Kit assists compressor start-up by providing additional starting torque on single-phase units and prolongs compressor motor life.

Duct Conversion Kit consists of 2 duct covers to be placed over the horizontal supply and return duct openings when the unit is converted for downshot applications.

Thermostats provide control for the system heating and cooling functions. Thermostat models are available in both program- mable and non-programmable versions.

Controls Upgrade Kit supplies high and low pressure safety protection and protects the unit from operating in unsuitable conditions.

Crankcase Heater provides anti-¯oodback protection for low- load cooling applications.

LP (Liquid Propane) Conversion Kit allows for conversion

from natural gas to liquid propane fuel.

Low NOx Kit for use with units being installed in California Air Quality Management Districts which require NOx emissions of 40 nanograms/joule or less.

Low-Ambient Kit (Motormaster II Control) allows the use of mechanical cooling down to outdoor temperatures as low as 0° F.

Solid-State Time Guard II Device provides short-cycling pro- tection for the compressor. Not required with corporate elec- tronic thermostats.

Filter Rack features easy installation, serviceability, and high- ®ltering performance for vertical applications.

High Altitude Kit is for use at 2001 to 6000 ft above sea level. Kit consists of natural gas ori®ces that compensate for gas heat operation at high altitude.

6

Page 6
Image 6
Bryant 583A manual Options and Accessories, FACTORY-INSTALLED Options, FIELD-INSTALLED Accessories

583A specifications

The Bryant 583A is a cutting-edge gas furnace designed for both efficiency and comfort, making it an ideal heating solution for residential applications. This model is particularly known for its exceptional performance and innovative technology, resulting in lower energy bills and a more consistent indoor environment.

One of the standout features of the Bryant 583A is its high-efficiency operation, boasting an AFUE (Annual Fuel Utilization Efficiency) rating of up to 95%. This means that a significant portion of the fuel consumed is converted into usable heat, making it an environmentally friendly choice that reduces energy waste. The design employs a two-stage heating operation, which allows the furnace to adjust its output according to the heating demands of the home, providing balanced warmth while minimizing energy consumption.

Built with advanced technology, the Bryant 583A includes a variable-speed blower motor that enhances comfort by distributing heated air more evenly throughout the home. This feature not only improves air circulation but also promotes quieter operation compared to standard single-speed blowers. The intelligent control system of the furnace permits compatibility with smart thermostats, which further enhances energy efficiency and user convenience.

Another notable characteristic of the Bryant 583A is its durability. Constructed with high-quality materials, this furnace is designed to withstand the rigors of continuous operation and to provide reliable service throughout its lifespan. Additionally, it features a heavy-duty heat exchanger that ensures optimal heat transfer while reducing the risk of breakdowns.

The Bryant 583A also prioritizes safety with features such as an automatic shut-off, which activates in the event of a malfunction, protecting both the system and the home. Additionally, its compact design allows for easy installation in a variety of spaces, making it a versatile choice for different home layouts.

In summary, the Bryant 583A is a remarkable gas furnace that combines high-efficiency performance, cutting-edge technology, and reliability. With its two-stage heating operation, variable-speed blower motor, and robust safety features, it caters to homeowners seeking both comfort and cost savings during the colder months. As a trusted name in heating solutions, Bryant continues to lead the way in delivering products that enhance home comfort while prioritizing energy efficiency and durability.