Bryant 597C VFACTORY WIRING 24-VFIELD WIRING, Field Splice Connection Ccontactor

Models: 597C

1 8
Download 8 pages 4.14 Kb
Page 6
Image 6
LEGEND

BRYANT

NON-PROGRAMMABLE

THERMOSTAT

MODEL AC

 

 

 

 

 

 

 

 

 

 

24 VAC HOT

 

R

 

 

 

 

 

 

 

24 VAC COM

 

C

 

 

 

 

 

 

 

HEAT STAGE 1

 

W/W1

 

 

 

 

 

 

 

COOL STAGE 1

 

Y/Y2

 

 

 

 

 

 

 

INDOOR FAN

 

G

 

 

 

 

 

 

 

 

 

 

 

 

OTHER

NON-PROGRAMMABLE

AC THERMOSTAT

 

 

 

 

24 VAC HOT

 

R

 

 

 

 

 

HEAT STAGE 1

 

W

 

 

 

 

 

COOL STAGE 1

 

Y

 

 

 

 

 

INDOOR FAN

 

G

 

 

 

 

 

BRYANT

PROGRAMMABLE

THERMOSTAT

MODEL AC

 

 

 

 

 

24 VAC HOT

 

R

 

 

 

 

 

INDOOR FAN

 

G

 

 

 

 

 

HEAT STAGE 1

 

W/W1

 

 

 

 

 

COOL STAGE 1

 

Y/Y2

 

 

 

 

 

NOT USED

 

O/W2

 

 

 

 

 

NOT USED

 

Y1/W2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24 VAC COM

 

C

 

 

 

 

 

NOT USED

 

B

 

 

 

NOT USED

 

L

 

 

 

 

 

OPTIONAL

 

 

S1

OUTDOOR

 

 

 

SENSOR

 

 

 

 

CONNECTION

 

 

S2

 

 

 

 

 

 

 

 

 

 

FK4C

AIR

 

FAN COIL

CONDITIONER

 

DH

J1 JUMPER

 

R

 

 

C

 

 

W1

J2 JUMPER

 

C

SEE

 

 

NOTE 2

W2

 

 

 

Y/Y2

 

 

G

 

 

O

 

 

Y1

 

 

 

 

A97363

FK4C

AIR

 

FAN COIL

CONDITIONER

 

DH

J1 JUMPER

 

R

 

 

C

J2

 

 

 

W1

JUMPER

 

C

SEE

 

NOTE 2

W2

 

 

Y/Y2

 

 

G

 

 

O

 

 

Y1

 

 

 

 

A97365

FK4C

AIR

 

FAN COIL

CONDITIONER

 

DH

 

 

R

J1 JUMPER

G

J2 JUMPER

W1

W2

Y/Y2 24-V FACTORY WIRING

C

SEE

NOTE 2

 

CFIELD SPLICE CONNECTIONFig. 5—Typical 24v Circuit Connections (Continued)

Y1 O

A97364

LEGEND

24-V FACTORY WIRING

24-V FIELD WIRING

FIELD SPLICE CONNECTION

CCONTACTOR

A97368

NOTES:

1.BRYANT THERMOSTAT-WIRING DIAGRAMS ARE ONLY ACCURATE FOR MODEL NUMBERS BEGINNING WITH TSTAT_ _ _ _ _ _ _.

2.WIRING MUST CONFORM TO NEC OR LOCAL CODES.

3.SOME UNITS ARE EQUIPPED WITH PRESSURE SWITCH(ES), TEMPERATURE SWITCH, OR 5–MINUTE COMPRESSOR-CYCLE PROTECTION. CONNECT 24V FIELD WIRING TO FACTORY-PROVIDED STRIPPED LEADS.

4.A LIQUID-LINE SOLENOID VALVE IS REQUIRED ON SOME UNITS.

5.THERMOSTATS ARE FACTORY CONFIGURED WITH 5–MINUTE COMPRESSOR-CYCLE PROTECTION AND

4–CYCLES–PER–HOUR LIMIT. SEE THERMOSTAT- INSTALLATION INSTRUCTIONS FOR DETAILS.

6.TO STAGE ELECTRIC-RESISTANCE HEAT, CONSULT OUTDOOR-THERMOSTAT INSTALLATION INSTRUCTIONS.

Fig. 5—Typical 24v Circuit Connections (Continued)

—6—

Page 6
Image 6
Bryant 597C VFACTORY WIRING 24-VFIELD WIRING, Field Splice Connection Ccontactor, Typical24v Circuit Connections Continued