COMBINATION RATINGS Continued
UNIT | INDOOR |
| INDOOR AIR CFM | TOT. CAP. BTUH |
|
| |||
|
|
|
|
|
|
|
| ||
SIZE | SECTION |
| High | Low | High |
| Low | SEER | EER |
| CK5A/CK5BA060 |
| 1750 | 1050 | 58,000 |
| 29,400 | 14.5 | 10.4 |
| CK5A/CK5BT060 |
| 1750 | 1050 | 58,000 |
| 29,400 | 14.5 | 10.4 |
| CK5A/CK5BX060 |
| 1750 | 1050 | 59,000 |
| 29,600 | 15 | 10.5 |
| CK5PA060 |
| 1750 | 1050 | 58,000 |
| 29,400 | 14.5 | 10.4 |
| CK5PT060 |
| 1750 | 1050 | 58,000 |
| 29,400 | 14.5 | 10.4 |
| CK5PX060 |
| 1750 | 1050 | 59,000 |
| 29,600 | 15 | 10.5 |
|
| COILS + 315(A,J)066155 VARIABLE SPEED FURNACE |
|
|
| ||||
| CC5A/CD5AA060 |
| 1750 | 1050 | 58,000 |
| 29,200 | 14.5 | 10.4 |
| CC5A/CD5AW060 |
| 1750 | 1050 | 58,000 |
| 29,200 | 14.5 | 10.45 |
| CE3AA060 |
| 1750 | 1050 | 58,500 |
| 29,200 | 14.5 | 10.5 |
| CK3BA060 |
| 1750 | 1050 | 58,000 |
| 29,400 | 14.5 | 10.45 |
| CK5A/CK5BA060 |
| 1750 | 1050 | 58,000 |
| 29,400 | 14.5 | 10.45 |
| CK5A/CK5BT060 |
| 1750 | 1050 | 58,000 |
| 29,400 | 14.5 | 10.45 |
| CK5A/CK5BX060 |
| 1750 | 1050 | 59,500 |
| 29,600 | 15 | 10.6 |
| CK5PA060 |
| 1750 | 1050 | 58,000 |
| 29,400 | 14.5 | 10.45 |
| CK5PT060 |
| 1750 | 1050 | 58,000 |
| 29,400 | 14.5 | 10.45 |
| CK5PX060 |
| 1750 | 1050 | 59,500 |
| 29,600 | 15 | 10.6 |
|
| COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE |
|
| |||||
| CC5A/CD5AA060 |
| 1838 | 1138 | 56,500 |
| 28,800 | 14.2 | 9.85 |
| CC5A/CD5AW060 |
| 1838 | 1138 | 58,000 |
| 29,400 | 14.5 | 10.2 |
| CE3AA060 |
| 1838 | 1138 | 58,500 |
| 29,600 | 15 | 10.45 |
| CK3BA060 |
| 1838 | 1138 | 57,500 |
| 29,600 | 14.5 | 10.1 |
| CK5A/CK5BA060 |
| 1838 | 1138 | 57,500 |
| 29,600 | 14.5 | 10.1 |
| CK5A/CK5BT060 |
| 1838 | 1138 | 57,500 |
| 29,600 | 14.5 | 10.1 |
| CK5A/CK5BX060 |
| 1838 | 1138 | 59,000 |
| 29,800 | 15 | 10.5 |
| CK5PA060 |
| 1838 | 1138 | 57,500 |
| 29,600 | 14.5 | 10.1 |
| CK5PT060 |
| 1838 | 1138 | 57,500 |
| 29,600 | 14.5 | 10.1 |
| CK5PX060 |
| 1838 | 1138 | 59,000 |
| 29,800 | 15 | 10.5 |
|
| COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE |
|
| |||||
| CC5A/CD5AA060 |
| 1838 | 1138 | 58,000 |
| 29,400 | 14.4 | 9.9 |
| CC5A/CD5AW060 |
| 1838 | 1138 | 58,000 |
| 29,400 | 14.5 | 10.05 |
| CE3AA060 |
| 1838 | 1138 | 58,500 |
| 29,600 | 14.5 | 10.05 |
| CK3BA060 |
| 1838 | 1138 | 57,500 |
| 29,400 | 14.5 | 9.95 |
| CK5A/CK5BA060 |
| 1838 | 1138 | 57,500 |
| 29,600 | 14.5 | 10 |
| CK5A/CK5BT060 |
| 1838 | 1138 | 57,500 |
| 29,600 | 14.5 | 10 |
CK5A/CK5BX060 |
| 1838 | 1138 | 59,000 |
| 29,800 | 15 | 10.35 | |
CK5PA060 |
| 1838 | 1138 | 57,500 |
| 29,600 | 14.5 | 10 | |
|
|
| |||||||
| CK5PT060 |
| 1838 | 1138 | 57,500 |
| 29,600 | 14.5 | 10 |
| CK5PX060 |
| 1838 | 1138 | 59,000 |
| 29,800 | 15 | 10.35 |
|
| COILS + 355MAV060080 VARIABLE SPEED FURNACE |
|
|
| ||||
| CC5A/CD5AA060 |
| 2000 | 1200 | 57,500 |
| 29,800 | 13.5 | 9.15 |
| CC5A/CD5AW060 |
| 2000 | 1200 | 59,500 |
| 30,000 | 14 | 9.4 |
| CE3AA060 |
| 2000 | 1200 | 59,500 |
| 30,000 | 14 | 9.4 |
| CK3BA060 |
| 2000 | 1200 | 58,000 |
| 30,000 | 13.5 | 9.25 |
| CK5A/CK5BA060 |
| 2000 | 1200 | 58,000 |
| 30,000 | 13.5 | 9.25 |
| CK5A/CK5BT060 |
| 2000 | 1200 | 58,000 |
| 30,000 | 13.5 | 9.25 |
| CK5A/CK5BX060 |
| 2000 | 1200 | 59,500 |
| 30,000 | 14 | 9.45 |
| CK5PA060 |
| 2000 | 1200 | 58,000 |
| 30,000 | 13.5 | 9.25 |
| CK5PT060 |
| 2000 | 1200 | 58,000 |
| 30,000 | 13.5 | 9.25 |
| CK5PX060 |
| 2000 | 1200 | 59,500 |
| 30,000 | 14 | 9.45 |
|
| COILS + 355MAV060100 VARIABLE SPEED FURNACE |
|
|
| ||||
| CC5A/CD5AA060 |
| 2000 | 1200 | 56,500 |
| 29,000 | 14 | 9.55 |
| CC5A/CD5AW060 |
| 2000 | 1200 | 58,000 |
| 29,400 | 14 | 9.5 |
| CE3AA060 |
| 2000 | 1200 | 58,500 |
| 29,800 | 14 | 9.55 |
| CK3BA060 |
| 2000 | 1200 | 57,500 |
| 29,600 | 14 | 9.4 |
| CK5A/CK5BA060 |
| 2000 | 1200 | 57,500 |
| 29,600 | 14 | 9.4 |
| CK5A/CK5BT060 |
| 2000 | 1200 | 57,500 |
| 29,600 | 14 | 9.4 |
| CK5A/CK5BX060 |
| 2000 | 1200 | 59,000 |
| 30,000 | 14.25 | 9.6 |
| CK5PA060 |
| 2000 | 1200 | 57,500 |
| 29,600 | 14 | 9.4 |
| CK5PT060 |
| 2000 | 1200 | 57,500 |
| 29,600 | 14 | 9.4 |
| CK5PX060 |
| 2000 | 1200 | 59,000 |
| 30,000 | 14.25 | 9.6 |
|
| COILS + 355MAV060120 VARIABLE SPEED FURNACE |
|
|
| ||||
| CC5A/CD5AA060 |
| 2000 | 1200 | 58,500 |
| 29,400 | 14 | 9.7 |
| CC5A/CD5AW060 |
| 2000 | 1200 | 58,500 |
| 29,400 | 14 | 9.75 |
| CE3AA060 |
| 2000 | 1200 | 59,000 |
| 29,800 | 14.25 | 9.8 |
| CK3BA060 |
| 2000 | 1200 | 57,500 |
| 29,600 | 14 | 9.65 |
| CK5A/CK5BA060 |
| 2000 | 1200 | 58,000 |
| 29,600 | 14 | 9.65 |
| CK5A/CK5BT060 |
| 2000 | 1200 | 58,000 |
| 29,600 | 14 | 9.65 |
| CK5A/CK5BX060 |
| 2000 | 1200 | 59,000 |
| 30,000 | 14.35 | 9.85 |
| CK5PA060 |
| 2000 | 1200 | 58,000 |
| 29,600 | 14 | 9.65 |
| CK5PT060 |
| 2000 | 1200 | 58,000 |
| 29,600 | 14 | 9.65 |
| CK5PX060 |
| 2000 | 1200 | 59,000 |
| 30,000 | 14.35 | 9.85 |
* Tested combination.
EER — Energy Efficiency Ratio
SEER — Seasonal Energy Efficiency Ratio
NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2.Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures.
3.Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4.Application of capillary tube coils is not recommended.