GASKET

FLOAT

 

 

 

 

PIN

 

 

 

ARM

 

RETAINER

 

 

 

 

 

 

 

 

BEARING

 

12 IN. LONG

 

VALVE BODY

 

 

SCREW

VALVE SEAT

 

WASHER

14 IN. BLUNT

SUPPORT

 

 

 

 

 

POINT SCREW

 

 

 

BRACKET

 

 

 

 

 

 

 

(LEFT HAND INSTALLATION SHOWN)

FLOAT VALVE ASSEMBLY

REINSTALLING MEDIA ASSEMBLY

A98370

Fig. 15ÐValve and Media Assembly for HUMBBWTR2019-A--

VIII. INSTALL HUMIDISTAT AND COMPLETE WIRING

1.Mount humidistat on inside wall or return-air duct in accordance with section INSTALLATION OF HUMIDIS- TAT on page 10.

NOTE: Wiring must comply with national electrical code and any local codes or ordinances that may apply. (See Fig. 17.)

HUMIDISTAT

MOTOR

24VAC

FURNACE

 

 

TRANSFORMER

 

HUMIDISTAT

(10-VA)

 

MOTOR

 

115V

24V

FIELD

 

 

WIRING

A96014

Fig.17ÐHumidistat Installation for HUMBBWTR2019-A--

IX. START-UP

1.Open saddle valve to permit water to flow to the solenoid valve.

2.Check all connections for water leaks.

3.Set thermostat to call for heat. Set humidistat at highest humidity setting to be sure the contacts are closed. After a few minutes of operation, check the drain connection for leaks and to see if water is flowing through humidifier.

4.Reverse thermostat and humidistat settings to insure proper shutdown.

5.Reset thermostat to normal setting. Reset humidistat to recommended setting.

X.FINAL STEPS

Attach humidifier maintenance instruction sticker to a visible location.

1.Inform homeowner of proper operation, maintenance, and humidistat setting.

a.If unit is installed during cooling season, close bypass damper, set humidistat for summer setting (OFF or lowest setting).

b. If installed during heating season, set unit for normal operation.

INSTALLATION OF HUMIDISTAT

The humidistat provides automatic control of humidifiers in central heating systems. It is designed for low voltage, wall, or surface duct mounting and contains a SPST snap-acting dustproof switch.

CAUTION: Disconnect power supply before making wiring connections to prevent possible electrical shock and equipment damage. Make wiring connections in accordance with Installation Instruction supplied with the humidifier.

1.Installer must be a trained, experienced service person.

2.Disconnect power supply before beginning installation.

3.Conduct a thorough checkout before leaving installation.

I. WALL MOUNTING (LOW VOLTAGE)

1.Choose a location for humidistat about 5 ft above floor on inside wall with average room temperature and relative humidity conditions. Maximum ambient temperature of selected location must not exceed 125°F. Humidistat may be mounted directly on wall.

2.Drill a small hole in wall and run low-voltage wiring to location chosen. Pull about 6 in. of wire through hole. Plug opening to prevent drafts from affecting humidistat opera- tion.

3.Remove knob, faceplate, and switch assembly from case by following steps listed below.

a.Remove knob by pulling away from casing. (See Fig. 18.)

b.Lift off faceplate, starting at right side. Left end of faceplate protrudes under lip of casing. (See Fig. 18.)

c.Remove switch by removing 2 screws in back of casing. Pressing tab on case. Lift out control. (See Fig. 19.)

4.Make connections to screw terminals on switch assembly. Re-install switch into casing Ð secure with 2 short screws.

5.Mount case horizontally over wires directly to wall using 2 long screws provided.

6.Replace faceplate and knob.

Ð10Ð

Page 10
Image 10
Bryant HUM-56-1 manual Installation of Humidistat, Wall Mounting LOW Voltage

HUM-56-1 specifications

The Bryant HUM-56-1 is a cutting-edge heating, ventilation, and air conditioning (HVAC) unit that has garnered attention in both residential and commercial sectors for its advanced features and efficient performance. Designed to provide optimal climate control, the HUM-56-1 incorporates several innovative technologies that set it apart from traditional HVAC systems.

One of the standout features of the Bryant HUM-56-1 is its high-efficiency design. The unit boasts an impressive Seasonal Energy Efficiency Ratio (SEER) rating, which indicates its ability to deliver maximum cooling with minimal energy consumption. This efficiency translates into lower utility bills and a reduced carbon footprint, making it an environmentally conscious choice for homeowners and businesses alike.

The HUM-56-1 employs advanced smart technology, including Wi-Fi connectivity and compatibility with smart home systems. This allows users to monitor and control their HVAC system remotely via mobile devices, providing convenience and flexibility. The unit also features programmable settings that enable users to customize their indoor climate according to their schedules, further enhancing energy savings and comfort.

Another key characteristic of the HUM-56-1 is its quiet operation. Equipped with sound-dampening features, the unit minimizes noise levels, ensuring a peaceful indoor environment. This is particularly beneficial for residential applications where noise disruption can impact daily life.

In terms of air quality management, the HUM-56-1 is designed to optimize indoor air quality. The unit is compatible with advanced filtration systems that remove allergens and pollutants from the air, making it an excellent choice for allergy sufferers. Additionally, the system’s ventilation capabilities ensure fresh air circulation, promoting a healthier living space.

Durability is a crucial aspect of the Bryant HUM-56-1. Constructed with high-quality materials, the unit is built to withstand various environmental conditions, ensuring longevity and reliable performance. Bryant also backs the HUM-56-1 with a comprehensive warranty, highlighting their commitment to quality and customer satisfaction.

Overall, the Bryant HUM-56-1 stands out in the HVAC market due to its efficiency, smart technology integration, quiet operation, enhanced air quality features, and durable construction. These characteristics make it a preferred choice for those seeking a reliable and effective climate control solution. Whether for residential or commercial use, the HUM-56-1 is poised to deliver outstanding performance and comfort all year round.