INSTALLATION OF HUMBBSFP1016-A--
FAN POWERED HUMIDIFIER
Bryant's
It is recommended to install the humidifier where it can be easily serviced. Pad access door can be easily converted from right to the left hand side. Always install humidifier downstream of an electronic air cleaner.
→I. INSPECT PACKAGE AND CHECK EQUIPMENT
Inspect contents of packaged humidifier. File claim with shipping company prior to installation, if shipment is damaged or incom- plete.
The package should contain:
1.Humidifier and media assembly
2.Humidistat
3.Template
4.Owner's Manual
5.Warranty Certificate
6.Solenoid valve
7.Saddle valve assembly with adapter
8.Four sheet metal screws
9.Foam tape
10.Noise suppressor (use for water pressure over 60 psi)
11.Worm clamp for
12.Humidifier maintenance instruction sticker
13.Bryant logo label
"N" COIL
HORIZONTAL
VERTICALHORIZONTAL
A97098
Fig. 7ÐInstallation of HUMBBSFP1016-A--
Fan-Type Humidifier
II.SELECT LOCATION (SEE FIG. 7.)
Humidifier must be installed on supply plenum only. If furnace has air conditioning coil, be sure humidifier does not interfere with coil ends. Remember to provide clearance for maintenance and evapo- rator pad removal.
To reverse pad access from right to the left side:
1.Remove side door and media pad assembly.
2.Remove 4 screws and separate top assembly from lower mounting base. (See Fig. 8.)
3.Rotate lower mounting base 180 degrees, so side access door is now on left.
4.Snap together top assembly to mounting base and reinstall screws.
5.Replace media pad assembly (with distributor reservoir up) and side access door.
A96049
Fig. 8ÐReversing Door Access
on HUMBBSFP1016-A--
CAUTION: When
IMPORTANT: Make sure front housing assembly with electrical cord is facing down.
| MEDIA PAD |
| ASSEMBLY |
| DRAIN |
| OUTLET |
HOUSING | VINYL DRAIN |
ENCLOSURE | TUBING |
DRAIN OUTLET |
|
| A97108 |
Fig. 9ÐMedia Pad Assembly Installation
III.PREPARE PLENUM OPENING (SEE FIG. 2.)
1.Use template for marking humidifier opening.
2.Tape in place on plenum making sure template is level.
IMPORTANT: For humidifier to operate properly it must be level and mounted on a vertical surface.
3.Drill four
4.Cut opening in plenum using heavy solid lines on template as a guide.