power on. System installation screens will automatically appear and will display the Equipment Summary screen when finished. The Equipment Summary screen will display REMOTE ACCESS near the bottom of the screen.
If REMOTE ACCESS is not displayed, check connections to the ABC wires as well as ensure the Yellow LED is lit on the System Access Module (this ensures the module has power). The green LED will be lit next to each ABC connection if the user interface has established communication.
IX. PIN NUMBER AND SERIAL NUMBER
The PIN and Serial number of the System Access Module are used by the system owner to register their system with Bryant. Remove the sticker containing the PIN number from the radio and install at the front of the Owner’s Guide. Also, write down the SAM serial number in the Home Owner’s Guide. The serial number can be found on the SAM packaging, at the bottom of the large SAM circuit board (see Fig. 3), or in the user interface Service Menu. If PIN number is lost or missing, it can be found by entering the Service Menu of the User Interface (10 second press of the Advance button) and looking at the Model/Serial Numbers screen. The PIN will be listed with the System Access Module model and serial numbers.
RS-232 Connector
An
Updating System Profile
The Evolution System will automatically send system information to Bryant’s computer servers within one hour after the system has been successfully installed. Access to the system via the internet or telephone will not be available until this occurs. The system can be forced to send its information through the following process if internet and telephone access is required immediately. Press and hold the RADIO TEST button for 15 seconds. When the button is first pressed, the red LED will turn on. Five seconds into the press, the yellow LED will turn on. 15 seconds into the press, the green COM1 LED will turn on. Release the button when the green LED turns on. The red LED will flash when messages are being sent. The red and yellow LED will flash when the SAM is waiting for message replies. Upon successful profiling, both green LEDs will be lit. If profiling is not successful, the red LED will be lit solid. The entire profiling process can take up to 15 minutes per Evolution System. If two systems are connected to one SAM, then the profiling process can take up to 30 minutes.
If the Evolution system ABC wiring is moved from connector 1 to connector 2 (or vice versa), or Evolution equipment has changed, the System Access Module must update Bryant’s servers with the new information. This will happen automatically within one hour, or can be manually forced with the process described above.
TROUBLESHOOTING
FAULT INDICATORS — Under normal operation, the Yellow and Green LED will be on continuously (solid). If the System Access Module does not receive communications with the Evolu- tion system, the Green LED will not be on. If there are faults present, the Yellow LED indicator will blink a two digit status code. The first digit will blink at a fast rate, the second at a slow rate.
STATUS CODE | DESCRIPTION |
45 | Board Failure |
61Radio out of range (no coverage for five minutes)
62Loss of communication with the radio
63Radio not registered with the local network
(unregistered for five minutes)
64 | Auxiliary sensor active |