Bunn 41170.0001A manual Program Functions, Brew Lockout ? No Done Yes Brew Oz A Done +

Models: 41170.0001A

1 9
Download 9 pages 1.54 Kb
Page 6
Image 6
BREW LOCKOUT ?

BREW LOCKOUT ?

NO DONE YES

BREW OZ A: 8.0

(-) DONE (+)

BREW METER A: 2

-+

BREW OZ B: 6.0

(-) DONE (+)

BREW METER B: 1

- Manual backgroundManual background +

ENTER SERVICE #

NO DONE YES

ENTER PASSWORD

0

0

0

SET PASSWORD

0 0 0

SET LANGUAGE ?

NOYES

UNITS

METRIC DONE ENG

SET TEMP: 200°

(-) DONE (+)

SET READY: 195°

(-) DONE (+)

HOT H2O LOCKOUT ?

NO DONE YES

PROGRAM FUNCTIONS

BREW LOCKOUT (YES/NO)

Setting to "YES" only allows brewing at or above the "SET READY" temp screen.

BREW OZ. (LARGE) (1-16)

Adjust brew volume for "LARGE" button.

BREW METER (LARGE) (1-5)

Simplified pulse brew adjustment. 1=Preinfusion. 2-5=pulse brew,

2 being the shortest pulse brew cycle, 5 the longest pulse brew cycle.

BREW OZ. (SMALL) (1-16)

Adjust brew volume for "SMALL" button.

BREW METER (SMALL) (1-5)

Simplified pulse brew adjustment. 1=Preinfusion. 2-5=pulse brew,

2 being the shortest pulse brew cycle, 5 the longest pulse brew cycle.

ENTER SERVICE #

Program service phone number to be displayed anytime there is a fault message.

ENTER PASSWORD

User must enter a 3 digit number to access remainder of adjustments. If no number has been pre programmed (0 0 0), then access is allowed.

SET PASSWORD (001-999)

Program any three digit number as a password.

LEVEL 2

SET LANGUAGE

Choose between English or Spanish.

UNITS

Choose between English or metric.

SET TEMP

Adjust tank temperature 185 to 205° F (85 to 96° C)

SET READY

Sets the minimum temperature allowable to start a brew cycle. Range: (2° to 20° F) or (2° to 10° C) below the set temperature.

HOT H2o LOCKOUT

Setting to "YES" will only allow dispensing of hot water at or above the "H2o READY" temp screen.