![H2O READY: 190°](/images/new-backgrounds/63395/6339513x1.webp)
H2O READY: 190°
ENTER ASSET # ?
NOYES
SetPulseBrew A ?
NO DONE YES
AIR TIME A: 20
SetPulseBrew B ?
NO DONE YES
AIR TIME B: 20
BREWS TO EMPTY
Enabl EnergySavr
NO DONE YES
BREW COUNT ##
NOYES
CALIBRATE FLOW ?
NOYES
FLOW COUNTS / 10 oz
NUMBER OF EJECTS
SINGLEDOUBLE
BREWS ON THIS SEAL
RESET NEXT ##
PROGRAM FUNCTIONS
HOT H2o READY
Sets the minimum temperature allowable to start dispensing hot water.
ENTER ASSET #
This function allows the you to enter in an optional asset number. This can be useful for tracking the usage or service of an individual machine within a group.
SET PULSE BREW (LARGE) Individually adjust on/off times.
AIR TIME (LARGE)
Time the pod is purged at the end of each brew cycle.
SET PULSE BREW (SMALL)
Individually adjust on/off times.
AIR TIME (SMALL)
Time the pod is purged at the end of each brew cycle. Can be disabled if brewer is set up to dispose pods under counter.
BREWS TO EMPTY
Set number of used pods in bin to turn on "EMPTY BIN" message.
ENABLE ENERGY SAVER
Choose to have the tank heaters turn off, or reduce the tank temp to (140° F) or (60° C) once the "SET IDLE TIME" has
BREW COUNTS
Retains the total number of brew cycles completed. There is one
CALIBRATE FLOW
Measure and enter the actual flow rate coming out of the sprayhead.
Number of pulses per ounce calculated during flow calibration.
FOR REFERENCE ONLY. DO NOT MANUALLY ADJUST!
You can set this to "DOUBLE" if you experience certain types of pods that do not reliably eject on single.
Use this counter to check/reset the seal replacement message.
CONTINUED