![LEVEL 3](/images/new-backgrounds/63395/6339517x1.webp)
| SET REFILL |
|
NO | THRESHLD | YES |
|
|
|
|
|
|
# | REFILL | ### |
DONE | (+) | |
|
|
|
FACTORY DEFAULTS
NOYES
AutoPOD BREWER
VERSION xx.xx
PROGRAM FUNCTIONS
SET REFILL
Press "YES" to access the refill screen. FOR TRAINED TECHNICIANS ONLY.
IMPROPER SETTINGS CAN RESULT IN OVER FLOW!
REFILL Adjust sensitivity of refill probe according to water quality. Always make sure that the # on the right is larger than the # on the left when water is contacting the tank refill probe.
FACTORY DEFAULTS
Reset all brew settings, calibrations back to factory presets. Requires following "INITIAL SETUP" procedure.
EXIT PROGRAM MODE TO MAIN SCREEN
Model:
Software version:
LEVEL 3
CAL TEMPERATURE NO SENSORS? YES
|
|
|
|
|
200˚ | CAL |
| 200˚ |
|
BrewTank | (+) |
| ||
|
|
|
|
|
WATER PUMP POWER
ReducedPowerLevel
# BrewsSealWarng
2nd THERM FAULT
DISABLEENABLE
CALIBRATE TEMPERATURE PROBE
Press "YES" to access the calibration screen.
Insert an accurate thermometer approximately
FACTORY USE ONLY
DO NOT ADJUST
REDUCED POWER LEVEL
Reduce power/number only when thin/loose pods cause brewing issues.
BREW SEAL WARNING
Sets the count number for "REPLACE SEAL" message.
FACTORY USE ONLY
DO NOT ADJUST
Page 9 | 41170.1 050312 |
|