Bunn 41170.0001A manual Level, Program Functions

Models: 41170.0001A

1 9
Download 9 pages 1.54 Kb
Page 9
Image 9
LEVEL 3

 

SET REFILL

 

NO

THRESHLD

YES

 

 

 

 

 

 

#

REFILL

###

(-)

DONE

(+)

 

 

 

FACTORY DEFAULTS

NOYES

AutoPOD BREWER

VERSION xx.xx

PROGRAM FUNCTIONS

SET REFILL

Press "YES" to access the refill screen. FOR TRAINED TECHNICIANS ONLY.

IMPROPER SETTINGS CAN RESULT IN OVER FLOW!

REFILL Adjust sensitivity of refill probe according to water quality. Always make sure that the # on the right is larger than the # on the left when water is contacting the tank refill probe.

FACTORY DEFAULTS

Reset all brew settings, calibrations back to factory presets. Requires following "INITIAL SETUP" procedure.

EXIT PROGRAM MODE TO MAIN SCREEN

Model:

Software version:

LEVEL 3

CAL TEMPERATURE NO SENSORS? YES

 

 

 

 

 

200˚

CAL -->

 

200˚

 

(-)

BrewTank

(+)

 

 

 

 

 

 

WATER PUMP POWER

(-) 100 (+)

ReducedPowerLevel

(-) 30 (+)

# BrewsSealWarng

(-) 9950 (+)

2nd THERM FAULT

DISABLEENABLE

CALIBRATE TEMPERATURE PROBE

Press "YES" to access the calibration screen.

Insert an accurate thermometer approximately 7-8˝ into tank. Adjust the number on the right with +/- until it matches reading of thermometer. Press the hidden program button.

FACTORY USE ONLY

DO NOT ADJUST

REDUCED POWER LEVEL

Reduce power/number only when thin/loose pods cause brewing issues.

BREW SEAL WARNING

Sets the count number for "REPLACE SEAL" message.

FACTORY USE ONLY

DO NOT ADJUST

Page 9

41170.1 050312

 

Page 9
Image 9
Bunn 41170.0001A manual Level, Program Functions