SERVICE TOOLS ?
NOYES
TEST OUTPUTS ?
NOYES
|
|
|
|
INDEX | B | MOTOR | |
DUMP | NEXT | LOAD | |
|
|
|
|
|
|
|
|
WaterInIet |
| # | |
ON | NEXT | OFF | |
|
|
|
|
AIR PUMP
ON NEXT OFF
VENT VALVE
ON NEXT OFF
HotWaterAir PUMP
ON NEXT OFF
WATER PUMP
ON NEXT OFF
TANK HEATER RELAY
ON NEXT OFF
TANK HEATER TRIAC
ON NEXT OFF
TEST SWITCHES ?
NOYES
PROGRAM SWITCH
TO EXIT
PROGRAM FUNCTIONS
SERVICE TOOLS allows testing of load components and switches.
It should only be used by trained technicians.
TEST OUTPUTS allows testing of load components by manually turning them
ON/OFF.
WARNING: HOT WATER WILL DISPENSE DURING SOME TEST MODES!
INDEX MOTOR DUMP runs the pod holder back to the pod ejection position. LOAD moves it out to the door open position. "B " indicates the assembly is in home postion.
WATER INLET
Activates the water inlet valve for the brew tank, and flow meter count.
AIR PUMP
Activates the air pump motor for the brew tank.
VENT VALVE
Activates the vent solenoid for the hot water tank.
HOT WATER AIR PUMP
Activates the air pump motor for the hot water tank.
WATER PUMP
Activates the water pump motor.
TANK HEATER RELAY
Activates the relay on the main control board for the tank heater.
TANK HEATER RELAY
Activates the triac on the main control board for the tank heater.
TEST SWITCHES allows testing of the membrane switches.
Press the hidden program switch to go back to previous screen. Pressing any other membrane switch will give corresponding readout for that switch.
CONTINUED
Page 8 | 41170.1 050312 |
|