Location:

The solenoids are located inside the autofill box.

Test Procedure:

1.Disconnect the dispenser from the power source.

2.Disconnect the white/violet, violet or blue wire and the white wire from the solenoid.

3.Connect the dispenser to the power source. Press the solenoid (water) switch, and with a voltmeter, check the voltage between the white wire, and either the blue, violet, or white/violet wire. The indication must be:

a)120 volts ac for two wire 120 volt models.

b)200 to 240 volts ac for two wire 200 or 240 volt models.

c)230 volts ac for two wire 230 volt models.

4.Disconnect the dispenser from the power source.

If voltage is present as described, proceed to #5.

If voltage is not present as described, refer to the Wiring Diagrams and check dispenser wiring harness.

5.Check for continuity across the solenoid valve coil terminals.

If continuity is present as described, refer to Fig. 17 and reconnect the wires to the solenoid.

If continuity is not present as described, replace the solenoid valve.

6.Check the solenoid valve for coil action. Connect the dispenser to the power source. Press the solenoid (water) switch and listen carefully in the vicinity of the solenoid valve for a "clicking" sound as the coil magnet attracts.

7.Disconnect the dispenser from the power source.

If the sound is heard as described and water will not pass through the solenoid valve, there may be a blockage in the water inlet before the solenoid valve or, the solenoid valve may require inspection for wear, and removal of waterborne particles.

If the sound is not heard as described, rebuild or replace the solenoid valve.

Solenoid Valve Repair:

1.Remove the wires from the solenoid valve to be repaired.

2.Turn off the water supply to the dispenser.

3.Remove the nut securing solenoid valve coil to the base.

4.Remove guide, washer, o-ring, plunger/spring and inspect for wear. Replace parts as required.

5.Install new o-ring in the solenoid valve base.

6.Install plunger/spring in the guide with spring to the bottom of the guide.

7.Install guide with the plunger/spring into the sole- noid valve base.

8.Install washer on guide.

9.Install coil with retainer on guide and secure with nut.

10.Refer to Fig. 17 and reconnect the wires.

WHI from Main Harness

 

WHI to Solenoid #2

WHI to Solenoid #1

BLU from Solenoid

WHI to Pump #1

Switch #1

VIO from Solenoid

 

 

Switch #2

 

WHI/VIO from

 

Solenoid Switch #3

 

WHI to Main

 

Harness

#1 AFPO-2

WHI to Pump #3

 

& 3 #2 AFPO-2

 

&3 #3 AFPO-3

ONLY

FIG. 17 SOLENOID TERMINALS

P1544

 

 

 

16

28791 040501

 

Page 16
Image 16
Bunn AFPO-2 SL service manual Solenoids, #1 AFPO-2, 3 #2 AFPO-2, 3 #3 AFPO-3 ONLY, SERVICE cont