SERVICE
FUSE AND FUSE HOLDER
|
|
|
|
| 1 |
|
|
|
| REFILL | 2 |
|
|
|
|
| |
|
|
| 3 |
| MAIN |
|
|
|
|
| POWER |
|
|
| WATER |
|
|
|
|
| INPUT |
|
|
|
| 1 | 1 |
|
|
|
| FLAVOR | FLAVOR |
|
|
|
| INPUT |
|
| |
|
| OUTPUT | 2 |
|
|
| 2 | WATER | 3 |
|
|
|
| OUTPUT |
|
| |
| FLAVOR |
|
|
|
|
| OUTPUT |
|
|
|
|
3 | WATER |
|
|
|
|
| OUTPUT |
|
|
|
|
FLAVOR |
|
|
|
|
|
OUTPUT |
|
|
|
|
|
WATER |
|
|
|
|
|
OUTPUT |
|
|
|
|
|
FIG. 4 FUSE HOLDER |
| P1516 | |||
|
|
Location:
The fuse holder is located on the lower right front of the autofill box just to the left of the power cord.
Test Procedure:
1.Disconnect the dispenser from the power source.
2.Remove cap and fuse from fuse holder.
3.Remove fuse from the cap.
4.Check for continuity through the fuse.
If continuity is present, reinstall the fuse, the fuse is operating properly.
If continuity is not present, replace the fuse.
Removal and Replacement:
Fuse:
1.Remove the cap from the fuse holder.
2.Remove fuse from the fuse holder and inspect. If blown, discard.
3.Install new 10 amp fuse in the fuse holder.
4.Reinstall fuse holder cap.
Fuse Holder:
1.Disconnect the dispenser from the power source.
2.Disconnect the wires from the rear of the fuse holder.
3.Remove the nut securing the fuse holder to the front of the main mounting panel.
4.Push the fuse holder through the hole in the panel.
5.Install new fuse holder and fuse through the hole in the panel.
6.Secure the fuse holder to the panel.
7.Refer to Fig. 5 and reconnect the wires.
BLK from Main
Wiring Harness
BLK to Main
ON/OFF Switch
| P1331 | |
FIG. 5 FUSE HOLDER TERMINALS | ||
|
11 | 28791 040501 |
|