Location:
The circuit board is located inside the autofill box, mounted on the right side of the solenoid mounting bracket under the switch panel.
Test Procedure:
1.Disconnect the dispenser from the power source.
2.Disconnect the ten pin plug on the main wiring harness from the connector on the circuit board.
3.Connect the dispenser to the power source. With a voltmeter, check the voltage across the black wire(#3) and the white wire (#6). The indication must be:
a)120 volts ac for two wire 120 volt models.
b)200 to 240 volts ac for two wire 200 or 240 volt models.
c) 230 volts ac for two wire 230 volt models.
4.Disconnect the dispenser from the power source.
If voltage is present as described, replace the circuit board.
If voltage is not present as described, refer to the Wiring Diagrams and check main wiring harness.
Removal and Replacement:
1.Remove the four
2.Remove the circuit board shield and set aside for reassembly.
3.Disconnect the ten pin plug from the main wiring harness to the circuit board.
4.Remove the six
5.Install new circuit board using
6.Place circuit board shield over the circuit board.
7.Install switch panel assembly and secure with four
8.Refer to Fig. 3 for circuit board ten pin connector.
| J4 |
| J1 |
| J2 |
| J3 |
| P1528 |
| FIG. 3 CIRCUIT BOARD CONNECTOR LOCATION |