USER NOTICES

Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condition. Replace any unreadable or damaged labels.

#00658.0000

#00831.0000

!CAUTION

When re-wiring the machine for operation on 120/208V or 120/240V, the replacement Power Supply Cord must be UL Listed Flexible Cord Type SO, SJO, SJTO, HSJO or SJOW, No. 12 AWG, 4 Conductor, Rated 90° C. Attachment Plug Cap must be UL Listed, NEMA 14-20P or L14-20P Configuration, Rated 125/250V, 20 AMPS. The Power Supply Cord must be at least 3 feet long and maximum 6 feet long (measured from Strain Relief to end of the Attachment Plug Cap.)

#34072.0000

Optional Field Wiring

120 V, 15.0 A, 1800 W

1PH, 2-Wire, 60HZ

#29710.0005 (3 Warmers)

CDBC(F)-DV BREWERS

Optional Field Wiring

120 V, 12.5 A, 1500 W

1PH, 2-Wire, 60HZ

#29710.0006 (No Warmer)

CDBC(F) APS-DV BREWERS

Optional Field Wiring

120/208-240 V, 15.6-17.5 A, 2980-3850 W

1PH, 3-Wire, 60HZ

#29710.0007 (3 Warmers)

CDBC(F)-DV BREWERS

Optional Field Wiring

120/208-240 V, 13.0-15.0 A, 2680-3550 W

1PH, 3-Wire, 60HZ

#29710.0008

CDBC(F) APS-DV & TC-DV

BREWERS

Page 3