until you hear the solenoid click
To decrease the amount of water for each brew cycle place an empty funnel in the funnel rails and an empty decanter or graduated vessel beneath the funnel. Press the "ON/OFF" switch. Momentarily press and release the "BREW" switch once for each ounce (approximate) of water to be removed from the existing setting. Press and hold the "BREW" switch until you hear the solenoid click
PULSE BREW SETUP PROCEEDURE
The pulse brew parameters (initial fill time, off times, and remaining on times) are entered using the following
1.First set the brew volume using the standard procedure in Brew Volume Setup.
2.Position an empty container under the sprayhead. Allow the tank to finish refilling. Make sure that the READY lamp is on, or that the BREW LOCKOUT function is turned off.
3.Press and hold the OFF/ON button. The brew valve will turn on after 10 seconds. Release the button. This begins the initial
4.The spray is now stopped and the off time setting has begun. Press the OFF/ON button momentarily to end the off time.
5.The spray is now on again and the remaining on time setting has begun. Press the OFF/ON button momentarily at the end of the desired remaining on time.
6.The setup is now complete and the parameters are stored in memory. The spray will continue the off and on cycles until the brew volume of step 1 is complete. Pressing the OFF/ON button again will terminate the brewing cycle, with the parameters stored in memory.
Page 9