TROUBLESHOOTING (cont.) |
|
|
| |
BREWING CIRCUIT (cont.) |
|
|
| |
PROBLEM |
| PROBABLE CAUSE |
| REMEDY |
Brew cycle will not start (cont.) | 8. Control board or dispense valve | If the switch panel is operating prop- | ||
|
|
|
| erly, proceed as follows. Attach a |
|
|
|
| voltmeter to the terminals of the |
|
|
|
| dispense solenoid. Connect the |
|
|
|
| brewer to the power source. Turn |
|
|
|
| on the brewer and press the BREW |
|
|
|
| switch. Voltage should be present |
|
|
|
| at the solenoid terminals. If voltage |
|
|
|
| is not present, refer to the wiring |
|
|
|
| diagrams and check the wiring har- |
|
|
|
| ness. If voltage is present, check for |
|
|
|
| continuity across the terminals of |
|
|
|
| the solenoid coil. If continuity is not |
|
|
|
| present, replace the solenoid (See |
|
|
|
| page 24). If continuity is present, |
|
|
|
| the valve may be stuck closed. |
Consistently low beverage level in | 1. Brew volume | Set up brewer according to instruc- | ||
the dispenser or beverage overflows | NOTE: Volume adjustments must | tions in section | ||
dispenser | be made with sprayhead installed. | Volumes. (See page 8) Using a stop | ||
|
|
|
| watch or second hand, time the |
|
|
|
| length of the brew cycle. Record |
|
|
|
| this time inside the top lid. If service |
|
|
|
| is ever needed again, use the time |
|
|
|
| as reference to determine if time |
|
|
|
| has changed. |
|
| 2. Lime build up | Inspect the dispense valve and | |
|
|
|
| sprayhead for excessive lime de- |
|
|
|
| posits. Delime as required. |
|
| 3. Dispense Valve | Remove dispense valve and clear | |
|
|
|
| any obstructions. Rebuild or re- |
|
|
|
| place valve if necessary. (See page |
|
|
|
| 24) |
Page 17 | 29707.1 082803 |
|