BUNN Espress ®
TROUBLESHOOTING
ES•2C™
PROBLEM | PROBABLE CAUSE |
Will not brew when any of the | Flowmeter |
batch buttons is pressed. |
|
(Continuous brew works as |
|
well as automatic refill.) | Solenoid valve |
|
Pump
Water is not hot or long re- Solenoid valve covery time.
Limit thermostat(s)
Tank heater
REMEDY
Check connections between the flowmeter and electronic control unit. Replace flowmeter.
Check voltage at terminals. If voltage is present when the dose switch is pressed, disconnect power supply, remove wires from coil terminals and check coil ter- minal continuity. If there is continuity replace solenoid.
When start switch is pressed, pump should turn on immediately. If this does not happen, check voltage at ter- minal block on the pump. If correct voltage is present, use a
Remove the solenoid valve and clear it of any obstructions. Rebuild or replace the valve if necessary.
Disconnect power supply , remove all wires check across limit terminals for continuity. If no continuity, replace limit thermostat(s).
Check tank heater terminals for correct voltage. If voltage is present and ma- chine is not heating properly, replace tank heater.