SCHEMATIC WIRING DIAGRAM FMDA DBC-3

 

 

 

 

L1

 

 

 

 

(WITH HOT WATER DISPENSE)

 

 

 

 

L2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN/YEL

 

 

 

 

 

 

TANK HEATER

 

 

 

CONTROL

 

 

 

LIMIT

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

 

 

THERMOSTAT

 

 

 

THERMOSTAT

 

 

TANK HEATER

 

 

 

 

 

 

 

BLK-16

 

BLK-16

 

 

BLK-16

 

 

BLK-16

 

 

 

 

 

 

WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLU/BLK

 

 

 

BLU/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

BLK

FAN

 

 

 

 

WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI

 

 

 

 

 

 

 

 

PNK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

BLK

 

 

PROBE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI

WHI

120V : 24V AC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J1-1

WHI/GRN

 

WHI/GRN

WHI/GRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/BLK

 

WHI/BLK

WHI/BLK

TRANSFORMER

 

 

 

 

OVERFLOW SWITCH

 

 

TANK INLET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PNK

 

 

 

 

 

 

GRN

 

 

BLU

RED

RED

 

VIO

 

 

 

 

 

WHI

 

GRN

 

 

 

 

 

 

 

 

 

SOL

 

 

 

 

J1-5

WHI/ORN

 

 

 

 

 

 

 

 

 

 

 

N.C.

 

 

 

 

 

 

 

 

 

WHI/BLU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J1-8

GRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J2-1

WHI/VIO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ORN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI

J2-5

BLU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

RIGHT DISPENSE

 

RIGHT WHIPPER

 

 

 

RIGHT HOPPER

 

 

 

 

 

 

O

 

 

WHI/VIO

SOL

WHI

 

WHI/VIO

M

WHI

 

WHI/BLU

RED

M

BLK

GRN

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

 

 

CENTER DISPENSE

 

CENTER WHIPPER

 

 

 

CENTER HOPPER

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

ORN

SOL

WHI

 

ORN

M

WHI

 

WHI/ORN

RED

M

BLK

GRN

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

 

 

LEFT DISPENSE

 

LEFT WHIPPER

 

 

 

LEFT HOPPER

 

 

 

 

 

 

C

 

 

TAN

SOL

WHI

 

RED

M

WHI

 

WHI/RED

RED

M

BLK

GRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

COLD DRINK OPTION (LEFT ONLY)

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

RED

 

RED

HOT/COLD SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

RED

 

WHI/YEL

SOL

WHI

RED

JUMPER PLUG MUST BE

 

 

 

 

 

 

 

 

 

 

 

TAN

 

 

 

 

 

 

 

 

 

 

 

TAN

 

TAN

 

 

 

 

RED

USED WHEN COLD

 

 

 

 

 

 

 

 

 

 

WHI

 

 

 

 

 

 

 

RED

DRINK FEATURE NOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INSTALLED

 

 

 

 

 

 

 

 

 

WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J3-1

RED/BLK

 

 

 

 

 

 

 

 

 

 

BLU

 

 

 

 

 

 

 

 

 

BRN/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/BRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOT WATER

 

 

 

 

WHI/VIO

 

 

 

 

 

 

 

 

 

RINSE

RUN

 

 

 

 

 

 

J3-5

WHI/BLU

 

 

 

 

 

 

 

 

 

 

 

 

BLU

SOL

WHI

 

 

 

 

ORN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN

 

 

 

 

 

 

 

 

 

GRN

 

 

 

 

 

 

 

 

 

 

 

BLU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J3-10

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/ORN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J4-1

RED-22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN-22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J4-4

GRN-22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

 

 

 

 

 

DISCONNECT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED-22 BLU-22

WHI/VIO-

 

 

BLU/BLK WHI

WHI BLU/BLK

 

BLK

 

22-BLU WHI/VIO-22

 

RED/BLK BRN/BLK WHI/BRN GRN

WHI/RED WHI/ORN WHI/BLU GRY

RED ORN WHI/VIO

 

 

 

 

 

 

BLU BLK

 

 

 

 

 

 

 

 

1-J1

 

1-J2

5-J2

 

 

TO ENABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RINSE TIMER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLOURESCENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUX. CONTROL PC BOARD

 

 

LAMP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BALLAST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN

BLK

 

CHASSIS

BLU WHI

 

 

 

DOOR

BLU WHI

 

 

WHI

 

BLU

BLK

RED

BLU

BLK

STARTER BLK

BLK RED

WHI BLU

230 VOLTS AC - 2 WIRE

SINGLE PHASE

50/60 HZ

29218.0004A 09/01 © 2001 BUNN-O-MATIC CORPORATION

 

SWITCH UNIT ASSY

 

 

GRN/BLK

 

 

 

RED/WHI

 

 

 

RED

 

 

 

BLK

 

 

 

WHI/BLK

 

 

 

ORN

 

 

 

BLU/WHI

 

 

 

BLU/BLK

 

 

 

RED/BLK

 

 

 

ORN/BLK

 

 

 

BLK/WHI

 

 

 

WHI/RED

 

 

 

BLU/RED

 

 

 

LEFT

CENTER

RIGHT

READY

S

M

L

STOP S

M

L

S

M

L

HOT

M

D

G

M

D

G

M

D

G

WATER

66

42672 122209

 

Page 66
Image 66
Bunn FMD-5, FMD-4 manual Schematic Wiring Diagram Fmda DBC-3 With HOT Water Dispense

FMD-4, FMD-5 specifications

The Bunn FMD-5 is a state-of-the-art coffee dispenser designed specifically for high-volume coffee brewing situations. This machine is ideal for restaurants, convenience stores, and other establishments that require an efficient and reliable coffee dispensing solution.

One of the primary features of the Bunn FMD-5 is its ability to brew and serve fresh, hot coffee with exceptional speed. The unit is capable of dispensing up to five gallons of coffee per hour, making it an ideal choice for busy environments where customer demand is high. The system utilizes a digital brewer control that allows for precise brewing temperatures and times, ensuring consistency in flavor and quality.

The FMD-5 also incorporates advanced technologies to streamline the brewing process. It features a programmable control panel that allows users to adjust settings based on their specific needs. This includes the ability to set brew cycles, control brew levels, and even program different brew strengths. The easy-to-read digital display shows real-time information, making it simple for operators to monitor the brewing process.

Another notable characteristic of the Bunn FMD-5 is its compact and space-saving design. Despite its robust brewing capacity, the unit is designed to fit easily in various retail and foodservice environments. The machine is also built with durable materials, ensuring longevity and reliability under heavy usage.

For maintenance, the FMD-5 is designed with user convenience in mind. It features removable components and accessible areas for easy cleaning and routine maintenance. Users can also benefit from preventative maintenance features that monitor the machine’s performance, alerting operators to any potential issues before they escalate.

In terms of versatility, the Bunn FMD-5 can accommodate different brewing systems and coffee types, allowing users to customize their offerings based on customer preferences. It supports pre-ground coffee and can also be adapted for different brewing styles, enhancing its usability in various coffee service environments.

Overall, the Bunn FMD-5 is an impressive combination of speed, efficiency, and flexibility, making it an excellent choice for any operation that demands high-quality coffee with minimal wait time. Whether you are serving a morning rush of customers or maintaining a steady stream of coffee through the day, the Bunn FMD-5 stands out as a reliable and efficient coffee dispensing solution.