SERVICE (cont.)
Tank Heater
Location:
The tank heater is located in the tank lid.
If voltage is present as described, proceed to #4.
If voltage is not present as described, replace the tank heater.
4.Remove the tank heater from the tank lid and in- spect it for cracks in the sheath.
P1993 |
FIG. 11 TANK HEATER |
If continuity is present as described, reinstall the tank heater. The tank heater is operating properly.
If continuity is not present as described, replace the tank heater.
Removal and Replacement:
1.Remove the wires to the tank heater.
2.Remove the
3.Remove the tank heater.
4.Inspect the tank heater gasket and replace if nec- essary.
5.Securely install the new tank heater. Be certain of a watertight seal.
6.Reconnect the wires, FIG. 12.
Test Procedure:
1.Disconnect the dispenser from the power source.
2.Check the voltage across the terminals of the tank heater with a voltmeter. Connect the dispenser to the power source. The indication must be 200 to 240 volts ac for 200 to 240 volt models.
3.Disconnect the dispenser from the power source.
BLU to Triac Assy | BLK to Limit Thermostat |
|
P1780
FIG. 12 TANK HEATER WIRING
19 | 10889 091599 |
|