TROUBLESHOOTING (cont.) |
|
|
|
PROBLEM | PROBABLE CAUSE | REMEDY | |
Water is cold (cont.) | 3. | Tank heater | Refer to Service - Tank heater for |
|
|
| testing procedures. See page 19. |
| 4. | Temperature control | Refer to Service - Electronic controls |
|
|
| for testing procedures. See page 12. |
|
|
| Check connections to Interlock |
| 5. | Dry plug protection | board and sheath of tank tempera- |
|
|
| ture probe. |
|
|
| Refer to Service - Electronic controls |
Water boils continuously. | 1. | Temperature control | for testing procedures. See page 12. |
|
|
| Inspect the tank assembly for excess |
| 2. | Lime | lime deposits. Delime as required. |
|
|
CAUTION - Tanks and tank components should be delimed regularly depending on local water conditions. Exces- sive mineral
Dispenser is making unusual noises. 1. Solenoid valve
2. Plumbing lines
3. Water supply
Ready indicator will not light. (when
temperature is within 4˚ of its se- 1. Temperature control lected setting.)
2. Ready Indicator LED
The nut on top of the solenoid valve must be tight or it will vibrate dur- ing operation.
Plumbing lines should not be rest- ing on the counter top.
(A)the dispenser must be connected to a cold water line.
(B)Water pressure to the dispenser must not be higher than 90 psi. In- stall a regulator if necessary to lower the working pressure to approxi- mately 50 psi.
Refer to Service - Electronic controls for testing procedures. See page 12.
Replace the indicator LED.
8 | 10889 072700 |
|