TROUBLESHOOTING (cont.)

PROBLEM

PROBABLE CAUSE

REMEDY

Automatic refill will not operate af- ter drawing hot water.

1.No water

2.Water strainer/flow control

3.Overflow protection switch

4.Liquid level system

5.Solenoid valve

Check plumbing and shut-off valves.

(A)Direction of flow arrow must be pointing towards dispenser.

(B)Remove the strainer/flow con- trol and check for obstructions. Clear or replace.

Refer to Service - Overflow protec- tion switch for testing procedures. See page 16.

Refer to Service - Electronic controls for testing procedures. See page 11.

Refer to Service - Solenoid valve for testing procedures. See page 17.

Refer to Service - Solenoid valve for testing procedures. See page 17.

Water flows into the tank continu-

1.

Solenoid valve

ously. (Dispenser disconnected from

 

 

power source).

 

 

Water flows into the tank continu-

1.

Liquid level system

ously (Dispenser connected to

 

 

power source).

 

 

Water is cold.

1.

Overflow protection switch

2. Limit thermostat

Refer to Service - Electronic controls for testing procedures. See page 11.

Refer to Service - Overflow protec- tion switch for testing procedures. See page 16.

Refer to Service - Limit thermostat for testing procedures. See page 15.

CAUTION - Do not eliminate or bypass limit thermostat. Use only B.O.M. replacement part #23717.0001.