TROUBLESHOOTING (cont.)
PROBLEM | PROBABLE CAUSE |
REMEDY
Automatic refill will not operate af- ter drawing hot water.
1.No water
2.Water strainer/flow control
3.Overflow protection switch
4.Liquid level system
5.Solenoid valve
Check plumbing and
(A)Direction of flow arrow must be pointing towards dispenser.
(B)Remove the strainer/flow con- trol and check for obstructions. Clear or replace.
Refer to Service - Overflow protec- tion switch for testing procedures. See page 16.
Refer to Service - Electronic controls for testing procedures. See page 11.
Refer to Service - Solenoid valve for testing procedures. See page 17.
Refer to Service - Solenoid valve for testing procedures. See page 17.
Water flows into the tank continu- | 1. | Solenoid valve |
ously. (Dispenser disconnected from |
|
|
power source). |
|
|
Water flows into the tank continu- | 1. | Liquid level system |
ously (Dispenser connected to |
|
|
power source). |
|
|
Water is cold. | 1. | Overflow protection switch |
2. Limit thermostat
Refer to Service - Electronic controls for testing procedures. See page 11.
Refer to Service - Overflow protec- tion switch for testing procedures. See page 16.
Refer to Service - Limit thermostat for testing procedures. See page 15.
CAUTION - Do not eliminate or bypass limit thermostat. Use only B.O.M. replacement part #23717.0001.
7 | 10889 091599 |
|