Bunn JDF-2N ADJUSTMENT & OPTIONAL SETTINGS cont Water Flow Testing and Adjustment, Mix Ratio

Models: JDF-2N

1 32
Download 32 pages 63.63 Kb
Page 14
Image 14
ADJUSTMENT & OPTIONAL SETTINGS (cont)
FIG 7 Adjusting Water Flow
Using 1/4” allen wrench

ADJUSTMENT & OPTIONAL SETTINGS (cont)

Water Flow Testing and Adjustment

1. Enter the “Pump Speed Programming” mode by simultaneously press- ing both “Hidden Switches” Fig 5 or Fig 6. Note that the beeper sounds twice and that the “PROGRAM” indicator begins flashing.

2. Place a graduated measuring cup or the large chamber of the empty brixing cup (BUNN-O-MATIC part number 33095.0000) under the ap- propriate dispense nozzle.

3. Press and hold the desired “Product Dispense Switch” Fig 5 (“+/Stop Switch” Fig 6, for portion control dispensers) for 5 seconds. Note that the beeper sounds once per second (6 times, total) during this period.

4. At the end of the 5 second period, the selected position will dispense water (no concentrate) for only 3 seconds.

5.Measure the water dispensed.

6.Adjust the water flow rate Fig 8, (clockwise to increase flow rate; counterclockwise to decrease flow rate) to the corresponding product mix ratio as follows:

Mix Ratio

Adjust water flow rate to:

Product

Brix %

 

(water + concentrate)

 

 

 

 

2+1

*3.75 fluid ounces (111 ml)

Prune Juice

16.0%

 

 

per 3-second test

Other

*

 

4+1

 

Orange Juice

11.8%

 

 

Pineapple Juice

12.8%

 

 

*4.0 fluid ounces (118 ml)

Cranberry Fruit Cocktail

14.0%

 

 

Grapefruit Juice

10.6%

 

 

 

5+1

per 3-second test

Lemonade

 

 

 

Apple Juice

12.0%

 

 

 

Fruit Punch

 

 

 

 

Grape Juice

13.0%

 

3+1 through 7+1

 

Other

*

 

Above 7+1

*4.0 fluid ounces (118 ml)

Other

*

 

 

per 3-second test

 

 

 

High Viscosity Juice

2.25-3.0 fl.oz. (66.5-89ml)

As Required

-

 

 

per 3-second test

 

 

 

 

 

 

 

 

*Maximum flow rate may be less depending on the water pressure supply at each location.

Note: Information for specific products listed in this table is to be used for reference only. Consult the product label for exact mix ratio and/or brix %. See product label for target brix %.

7.Repeat steps 3 through 6 as necessary until the correct water flow rate is achieved.

8.Repeat steps 3 through 7 for the remaining dispense positions.

9.Exit the “Pump Speed Programming” mode by simultaneously pressing both “Hidden Switches”. Note that the beeper sounds twice and the “PROGRAM” indicator extinguishes.

14

38310 010406

 

Page 14
Image 14
Bunn JDF-2N manual ADJUSTMENT & OPTIONAL SETTINGS cont Water Flow Testing and Adjustment, Mix Ratio, Product, Brix %