Dispense Fault List

“REFILL” indicator

Beeper

Fault

2 flashes

2 beeps

Dispense station locked out.

3 flashes

3 beeps

DISPENSE/RINSE sensing fault.

4 flashes

4 beeps

DISPENSE/RINSE knob mis-positioned.

5 flashes

5 beeps

Pump motor stalled/speed sensor inoperative.

All “REFILL”

3 beeps

Dispenser locked out.

indicators flash

 

 

3 times

 

 

Cooling Fault List

 

 

Fault Code

“COOLING”

DBC display

Fault

Fault

 

indicator

(optional)

 

Priority

8

8 flashes every

fault 8

Bath water level low.

1

 

5 seconds

 

(Also lights all “WATER” indicators)

 

7

7 flashes every

fault 7

Bath temperature probe short circuit.

2

 

5 seconds

 

 

 

6

6 flashes every

fault 6

Bath temperature probe open circuit.

3

 

5 seconds

 

 

 

5

5 flashes every

fault 5

Cabinet temperature probe short circuit.

4

 

5 seconds

 

 

 

4

4 flashes every

fault 4

Cabinet temperature probe open circuit.

5

 

5 seconds

 

 

 

3

3 flashes every

fault 3

Cooling system failure

6

 

5 seconds

 

(disables all dispense functions)

 

0

On steady

Bath/cabinet

Bath and cabinet temperatures excessive.

7

 

temperatures

 

 

 

2

2 flashes every

Bath/cabinet

Bath temperature excessive.

8

 

5 seconds

temperatures

 

 

1

1 flash every

Bath/cabinet

Cabinet temperature excessive. (Disables all

9

 

5 seconds

temperatures

dispense functions, flashes, all REFILL and

 

 

 

 

WATER indicators, and sounds the beeper

 

 

 

 

when temperature is excessive for more than

 

 

 

 

6 hours.)

 

 

 

 

 

 