TROUBLESHOOTING (cont.) |
|
|
PROBLEM | PROBABLE CAUSE | REMEDY |
Water leak filling drip tray or around | 1. Initial fill/setup | Some expansion normal. May fill |
dispense deck area |
| drip tray during initial ice block |
|
| formation |
| 2. Dispense deck | Inspect or replace fittings clamps, |
|
| |
|
| nect fittings. |
|
| NOTE: Dispense deck area slopes |
|
| to drain tube that leads to the drip |
|
| tray. |
| 3. Water pressure greater than | Install water pressure regulator and |
| 100psi | reduce to 50 psi. |
Water leaking beneath machine | 1. Bath tank overflow. | A) Bath fill valve - check for closed |
|
| position or replace leaking valve |
|
| B) Check all internal water connec- |
|
| tions. |
| 2. Condensation from cabinet cool- | Check for routing of condensation |
| ing coil. | tube to drip tray. |
Erratic spray during dispense | Dispense nozzle mixer missing or | Replace mixer. |
| broken |
|
Dispense nozzle dripping water | Dispense solenoid. | Replace dispense deck solenoid. |
Can't access programming | Programming password feature | See Password Protection to access |
| activated. | programming or reset password |
|
| to zero or change programming |
|
| password. |
| Dispense touchpad | Check for continuity on half and full |
|
| moon buttons. If no continuity when |
|
| pressed, replace touchpad. |
25 | 38310 010406 |
|