Bunn LCA-2A, LCC-2, LCA-2 PC manual BIB Empty Lockout Feature, Brew Temperature Lockout Feature

Models: LCA-2 PC LCA-2A LCC-2

1 36
Download 36 pages 62.09 Kb
Page 13
Image 13
BIB Empty Lockout Feature

Rinse Procedure:

1.Open the cabinet door and select Rinse on the Function Selector switch – close the door.

2.Place a 2 Liter (1/2 Gal) container under the Left dispense tip.

3.Activate the Left dispenser until water flow stops automatically, approximately 20 sec.

4.Repeat Steps 2 & 3 for the Right dispense tip.

The Rinse LED will turn OFF, when the Rinse procedure has been satisfied for both sides.

5.Open the cabinet door and select Normal on the Function Selector switch – close the door.

1 5

BIB Empty Lockout Feature

The dispenser can be set to not dispense product when the concentrate BIB is empty. To enable this feature, first calibrate the Empty BIB Threshold (refer to Field Calibrating the Empty BIB Warning). Then enable the BIB Empty Lockout feature (refer to the BIB Empty Lockout menu in Programming the Dispenser). The dispenser will now Lockout dispensing and flash the Right or Left “REFILL LED” corresponding to the empty BIB. Once the BIB has been replaced, PRIME the concentrate line (refer to Priming the Concentrate Lines) and then dispense mixed product until the “REFILL LED” goes out. NOTE: If the dispenser fails to clear the BIB Empty Lockout, repeat the Priming operation a second time to insure the concentrate is flowing properly.

Brew Temperature Lockout Feature

The dispenser can be set to not dispense product if the hot water is not up to the preset READY temperature. To enable this feature set the READY temperature to the minimum allowable dispense temperature. Then enable the Brew Lockout feature, refer to READY TEMP and BREW LOCKOUT, in Programming the Dispenser.

13

34766.1 010313

 

Page 13
Image 13
Bunn LCA-2A, LCC-2, LCA-2 PC manual BIB Empty Lockout Feature, Brew Temperature Lockout Feature